Instruction manual
INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing or Installing Circuit Cards
Page 5-35Circuit Card Settings
5
10. Remove the remote maintenance circuit card from the MAP/5P. See
‘‘Removing a Circuit Card’’
for the procedure.
11. Make sure the COM2 port is correctly connected to the motherboard.
12. Replace the dress cover. See ‘‘Replacing the Dress Cover’’
in Chapter 4,
‘‘Getting Inside the Computer’’, for power removal procedures.
13. Apply power to the MAP/5P. See ‘‘Restoring Power to the MAP/5P’’
in
Chapter 4, ‘‘Getting Inside the Computer’’
for this procedure.
14. Reboot the Lucent I
NTUITY system. See ‘‘Rebooting the System’’ in Chapter
3, ‘‘Common System Procedures’’, for the procedure.
15. Enable COM2 by changing the
Serial Ports 16550 Compatible
UART 2
to
02F8, IRQ3
.
This setting is located in the CMOS advanced option settings for the CPU.
See ‘‘Verifying the CMOS Settings’’
in Chapter 7, ‘‘Replacing Other
Components’’, for the procedure.
16. Reboot the Lucent I
NTUITY system. See ‘‘Rebooting the System’’ in Chapter
3, ‘‘Common System Procedures’’, for the procedure.
17. Install the modem. See Chapter 5, “Administration and Test for Lucent
I
NTUITY Peripherals,” in
Lucent
I
NTUITY
Messaging Solutions Release 4.0
MAP/5P System Installation
for the procedure.
18. Contact the remote maintenance center and inform them that the remote
maintenance circuit card has been removed, the COM2 port has been
enabled, and the modem has been installed.
19. The remote maintenance center will complete the procedure.
NOTE:
At this point the modem should have 3 LEDs lit.
20. Have the remote maintenance center login through the modem and
change the tsc password back to the original.