Instruction manual

INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing or Installing Circuit Cards
Page 5-34Circuit Card Settings
5
Figure 5-22. Software Remove Screen
3. Locate and record the numbers for the
RMBset
software package.
4. Press .
The system displays the following message:
Select package(s) you wish to process (or ‘all’ to
process all packages). (default: all) [?, ??, q]
5. Enter the first number you recorded in Step 3
.
The system displays the following message:
The following set is currently installed:
<package title> <package information>
Do you want to remove this set [y, n, q]
6. Enter y
7. Repeat Step 5
and Step 6 for all remote maintenance circuit card
packages.
8. Stop the voice system. See ‘‘Stopping the Voice System’
in Chapter 3,
‘‘Common System Procedures’’, for the procedure.
9. Shut down the Lucent I
NTUITY system. See ‘‘Shutting Down the Lucent
Intuity System’’ in Chapter 3, ‘‘Common System Procedures’’, for the
procedure.
CONTROL D