Instruction manual

INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing or Installing Circuit Cards
Page 5-15Circuit Card Settings
5
The Ethernet LAN circuit card is software configured. The default software
configuration is as follows:
IRQ - 10
I/O base address - 280
RAM base address - D8000
See ‘‘General Procedures’’
above for the Ethernet LAN circuit card installation
procedure.
Installing the LAN Circuit Card
Installation of the Ethernet LAN circuit card must be done in the following
sequence of operation.
1. Install the Ethernet LAN circuit card in the MAP/5P. See “Component
Assignments” in Appendix A, ‘‘System Configuration’’, for the correct slot.
2. Restore power to the system. See “Restoring Power to the MAP/5P
” in
Chapter 4, ‘‘Getting Inside the Computer’’
, for the procedure.
3. Administer the TCP/IP. See Chapter 8
,
Initial Administration and Testing
for TCP/IP Networking and Message Manager,” in
Lucent I
NTUITY
Messaging Solutions Release 4 MAP/5P System Installation
for more
information on TCP/IP administration.
4. Shut down the system. See “Shutting Down the Lucent
Intuity System” in
Chapter 3, ‘‘Common System Procedures’’
, for the procedure.
5. Cable the Ethernet LAN circuit card. See Chapter 4
,
Cable Connectivity,”
in
Lucent I
NTUITY
Messaging Solutions Release 4 MAP/5P System
Installation
for more information on TCP/IP administration.
6. Reboot the system. See “Rebooting the System
” in Chapter 3, ‘‘Common
System Procedures’’, for the procedure.
Configuring the LAN Circuit Card
To configure the LAN circuit card, do the following:
1. Enter
smc_setup
The system displays the SMC LAN Adapter Setup screen (Figure 5-9
).