lee le Lil eat The Ei140RC series is supplied with an East-Fit base that allows very quick and simple installation of the Smoke Alarm, combined with simple detector head removal and replacement The East-Fit base automatically connects both mains power and battery as the defector head slides on to the East-Fit base. Up to 12 Smoke/Heat Alarms can be interconnected so that when one senses fire all the units alarm. Interconnection can be achievable by hardwired or through a Radiology Base, the EI168RC.
ee ea 1. Switch off mains power to Alarm (green light on cover should go out). Remove unit as shown In "ALARM REMOVAL" section on page 11. . Locate battery slot In base of Alarm as shown below. . Uncle battery from battery snap connectors. . Connect naw battery by clipping back on fo battery snap connectors. Use only 9V Alkaline battered Duracell MN1604, Energizer 522. Other batteries can cause problems. ‘Wa recommend that the “replace by date” on the battery should still have at least 2 years to go.
5. Interconnected Alarms only Test the first unit by pressing the button for 10 seconds. All the units should alarm within 10 seconds of the first hom sounding. The red light on the first unit only will flash about once a second. On releasing the button the local Alarm will stop sounding Immediately and the remote Alarms will stop sounding approximately 3 seconds later (If testing using RF Interconnection this could take slightly longer). This will verify that the Interconnect Is working.
Other than the cleaning described above, no other customer servicing of this product Is required. Repairs, when needed, must be performed by the manufacturer. All Alarms are prone to dust and Insect Ingress which can cause malfeasance alarms or allure to alarm. In certain circumstances even with regular cleaning, contamination can build up in the smoke sensing chamber causing the Alarm to sound or fail. If this happens the Alarm can be resumed to us for servicing or replacement.
Planning Your Escape Roue Use the Smoke / Heat Alarm Test Buttons to familiarize your family with the Alarm sound and to practice fire drills regularly with all family members. Draw up a floor plan that will show each member at least 2 escape routes from each room in the house. Children rand to hide when they don't know what to do. Teach children how to escape, open windows, and uss roll up fire ladders and stools without adult help. Make sure they know what to do Hf the alarm goes off. 1.
/ Heat Alarm as recommended In the ‘INSTALLER INSTRUCTIONS’ section significantly Improves the probability of early detection. The Alarm may not be heard. WARNING: Experience has shown that children may not be woken by fire alarm tones. It is important that children are never Sift alone in a house. Families should have a fire escape plan that is rehearsed, so that everyone knows how to escape when fire occurs.
get HE fT 1. ALARM SOUNDS FOR NO APPARENT REASON: (1) Identify the alarm source. On interconnected units, the red light on the cover will flash rapidly only on the unit which is the source of the lama. If an optional Ei1526RC Control Switch or an Ei450 Alarm Controller is installed, press Locate when the system is sounding to identify source of alarm. (2) Check for fumes, steam efc. from the kitchen or bathroom. Paint and other fumes can cause nuisance/ false alarms.
ee 1 LEGATO CORRECT SITING POINT GAS "ALARM SHOULD BE CLING MOUNTED AT LEAST 300mm FROM WALLS & OBSTRUCTIONS, IDEALLY CENTRALLY IN ROOM AREA 2 FIX & WIRE BASE PLATE WIRE TO TERMINALS ON THE BASE PLATE AND FIX BASE PLATE TO CEILING USING THE FIXINGS PROVIDED 3 ‘SLIDE ON ALARM FE ‘SLIDE ALARM ONTO BASE PLATE. A CLICK SHOULD BE HEARD AS THE TAMPER-PROOF CATCH ENGAGES ATTENTION: THIS SECTION IS ONLY A GUIDE.
dda Data afl el The advice hers follows the guidance In British Standard BS 5839-6: 2013 In general (for further Information see the BS standard Itself). The main reason for fitting Smoke & Heat Alana in dwellings is to ensure that when there is a fire, sufficient early waning is given so that everybody can escape safely. This means that the fire alarms should ideally be located near all potential sources of fires and that the alarm should be heard throughout the house — particularly in the bedrooms.
ROI Requirements gs sp1e201y) IIH OPTIMUM PROTECTION for dwellings whets occupants may be st high risk {s.g. sidereal) Optimum Protection LD1: As LD2, but elo Including tics loft / other spaces in which & firs might start (apart from toilets or bathroom).
Selecting Alarm Type ele TE a Ee Locations Hall, Corridors, Escape Routes Chansons X X [vw Ling Rooms Bedrooms.
Lelia The locations must comply with applicable building regulations. Hot smoke rises and spreads out, so a central selling position Is the preferred location. The alr Is “dead” and does not move In comers, therefore Smoke & Heat Alarms must be mounted away from comers. Place the unit = At least 0.3m away from walls. See Figure 1 At least 0.3m from any light fitting or decorative object which might obstruct smoke / heat entering the Alarm.
«Near a decorative object, door, light fitting, window molding enc, that may prevent smoke or heat from entering the Alarm. + Surfaces that are normally warmer or colder than the rest of the room (e.g. attic hatches). Temperature differences might slop smoke or heat from reaching the unit. » Next to or directly above heaters or air conditioning vents, windows, wall vents stc. that can change the direction of airflow. + In very high or awkward areas (e.g.
WARNING: Mans operated Alarms should be Installed and Interconnected by a squalled electrician In accordance with the Regulations for Electrical Installations published by the Institution of Electrical Engineers (BS7671). Allure to Install this Alarm correctly may expose the user to shock or fire hazards. WARNING: The Alarm must be continuously powered 24 hours a day so it is important that it is not on a circuit that can be muted off by a switch.
« check that the Interconnect wire is NOT connected to Live, Neutral or Earth. Do not use an Earth wire for the Interconnect line. N.B. The Alarm does not need to be earthed. However the terminal marked S Is provided for the convenience of the Installer so that any copper Earth wire or cable colored green & yellow, can be safely terminated. To Interconnect the Alabamans connect all the IC terminals together as shown In Figure 6. 4.
Ensure the alarm operates correctly see “TESTING & MAINTENANCE" section on page 3. Interconnecting Alarms Note: A maximum of twelve Ei141RC / Ei144RC / Ei146RC Smoke or Heat Alarms may be interconnected. Up to 8 additional accessories may also be connected. If you wish to connect more than 12 Alarms contact your Systems using more than 3 or 4 Alarms must ba very carefully planned to ensure nuisance/false alarms are not excessive. e.g. from cooking fumes or steam.