Data Sheet

P
RODUCT
S
PECIFICATION
E2xFxWx 12W PS EuPII
Page
5/21
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 21 03 12 B
3.3 Output Specification
Parameter Key Min Typ. Max
Unit
Test Cond.
Output Voltage U
2
5 24 V 0 – 1,5A
Output voltage
tolerance
T
U2
3 % at PCB
Output Current I
2 Nominal
1,5 A
Max. Overload
current
I
2
Overload
180
150
% of I
2
Nominal
U
IN
= 264V
U
IN
= 90V
Output Power P
2
12 W
Ripple Voltage
U
2,rms
50 mV
rms
Output voltage tolerance
at end of EGSTON
standard cable
1,5m/0,5mm
2
U2
+3/-10
+3/-5
%
at 5-12,9V
at 13-24V
The unit is not long time over-current proof. If the unit is powered longer than 1
min in overload conditions (current range between I
2 Nominal
and I
2
Overload
), the
device can be damaged. The period between two overload conditions has to
be at least 15 minutes.