Data Sheet
P
RODUCT
S
PECIFICATION
E2xFxWx 12W PS EuPII
Page
16/21
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 21 03 12 B
8 S
AFETY
The units pass the following tests:
8.1 Dielectric Strength
The input isolation test voltage is
3kV 50/60 Hz for standard and household applications / 4KV 50/60Hz for
medical application , sinusoidal waveform.
Test duration is 2 seconds for 100% test, 1minute for lot-test.
8.2 Over-current Protection
The unit is not long time over-current proof. If the unit is powered longer than 1
min in overload conditions, the device can be damaged. The period between
two overload conditions has to be at least 15 minutes.
8.3 Single Component Failure
A single component failure does not cause any damage to persons or ambient
(fire, explosions, etc).
8.4 Short Circuit
The power supply is designed with a short circuit protection. A shortened
output does not cause any damage to persons or ambient (fire, explosions,
etc.) After removing this conditions the unit fulfills the specification.