Datasheet

EGSTON Standard
E2xFxWx 12W
Tel: (++43) 2984 / 2226-0
Fax: (++43) 2984 / 2226-1293
E-Mail: info@egston.com
www.egston.com
Rev. D
© 12/2011 EGSTON System
Electronics Eggenburg GmbH
Grafenbergerstraße 37
A-3730 Eggenburg, Austria
Generic Product Code
Voltage Tolerance:
3 3% on PCB
1 1% on PCB
Options:
L Power On LED
C Current Regulation
F Functional Earth
Application Area:
S Information Technology
H Household
M Medical electrical device
Housing:
E Euro Plug-In
U US, Canada Plug-In
G United Kingdom Plug-In
C Changeable Plug
D Desktop
P PCB Module
O Open Frame
E 2 _ F _ W _ _ _ _ _
Typical output chart
Overload
Current
Overload Area
Nominal
Foldback
Voltage
Specified Area
Standard power supply
Specifications
Dimensions Length Width Height
30W Wall Plug In
Housing (without
plug)
95 42 29.5 mm
Desktop Housing 120 54 38 mm
PCB Mount
Housing
83.9 44.2 28.4 mm
Input Parameter Key Min Typ Max Unit
Input voltage U
1
90 264 V
Input current I
1
3 110 300 mA
Input frequency f
1
47 50 63 Hz
Op. Temperature T 0 40 °C
80 %
Efficiency
η
According EuP Tier II
Output Parameter Key Min Typ Max Unit
Output Power P
2
12 W
Output Voltage U
2
5 24 V
Output current I
2
1.5 A
Ripple voltage U
RRMS
50
mV
RMS
Output voltage
tolerance at PCB
U2
3 %
Output voltage
tolerance at end
of EGSTON
standard cable
1,5m/0,5mm
2
U2
5-12,9V:
+3/-10
13-24V:
+3/-5
%
Constant Voltage
Nominal
Current
Voltage
Specified Area
Constant Current
With current regulation option