User's Manual
EWB160031M User manual
Proprietary & Confidential Information Egis Technology Inc.
Doc. NO:
3. General Specification
3.1 Voltages
3.1.1 Absolute Maximum Ratings
Symbol Description Min. Max. Unit
VBAT Input supply Voltage -0.3 3.6 V
Operating temperature -20°C to 70°C
Storage temperature -40°C to 85°C
3.1.2 Recommended Operating Ratings
Test conditions: At room temperature
Symbol Min. Typ. Max. Unit
VBAT 2.7 3.3 3.6 V
Test conditions: At operating temperature -20°C ~70°C
Symbol Min. Typ. Max. Unit
VBAT 2.7 3.3 3.6 V
3.2 Crystal Specification
Parameters Conditions Min. Typ. Max. Unit
Nominal Frequency 22 MHz
Load Capacitance
10 pF
Operating Temperature
-20 +75
℃
Frequency Tolerance
25℃±3℃
-10 +10 ppm
Frequency Stability
OperatingTemp.Range
-10 +10 ppm
Drive Level
100 uW
ESR
40 ohm