User`s manual

- 39 -
Appendix A – Special Functions
There are some special functions that are accessed from the Flight Settings screen that are not on
the menu. In general, you will probably not need to use these functions very often, if at all, but
you need to be aware of them in case you do.
Master Reset
A master reset completely clears all flight memory, and resets the flight settings to the defaults.
The default settings are:
Launch Detect Altitude: 200
Burn/Coast Samples/sec: 10
Interval (ms): 1000
Descent Samples/sec: 2
Interval (ms): 500
Main Enable: 0 (off)
Main Altitude: 300
Main ON-Time: 2
CHB Enable: 0 (off)
CHB ON-Time: 2
Burn Timer: 2
Airstart Delay: 0
Mach Timer: 2
Telemetry: 0 (off)
To perform a Master Reset, hold the Ctrl and Y keys down together at the Flight Settings screen,
you will then see this screen:
Eggtimer Build-1.45 Master Reset
**** WARNING ****
DO YOU REALLY WANT TO CLEAR ALL FLIGHT MEMORY???
Press BUTTON for 10 seconds to Reset
To perform the reset, you need to hold the Button on the Eggtimer down for at least 10 seconds.
When you do, you will hear a long confirmation tone, then you will see a progress screen as the
memory pages are reset. Leave the Eggtimer alone until the process is complete. When the
reset is complete, you will see “Master Reset Completed”, you need to reset or power down the
Eggtimer before you can use it.
Memory Dump
The Memory Dump writes comma-separated-variable (CSV) data to the serial port containing
the data in every memory location. This function is primarily used by the Eggtimer Technical