User manual

Norsk
Bruk
Side 148
Tillatte verdiområder
for batteriparametrene
(bly/syre, bly/gel eller
AGM)
Standard
innstilling
Min.
Maks.
Egen
verdi:
Utsatt oppstart
60 sek
2 sek
300 sek
Oppstartspenning
12,3 V
11,0 V
13,0 V
Utkoblingsspenning
14,2 V
13,5 V
14,7 V
Utkoblingsstrøm
- EFOY COMFORT
80/140
- EFOY COMFORT 210
2,0 A
4,0 A
1,0 A
4,0 A
10,0 A
10,0 A
Absorpsjonstid
180 min
0 min
300 min
Max. charge time
24 h
2 h
120 h
Altitude up to
1500 m
0 m
2000 m
Tillatte verdiområder
for batteriparametrene
LiFePO4
Standard
innstilling
Min.
Maks.
Egen
verdi:
Utsatt oppstart
60 s
2 s
300 s
Oppstartspenning
13,3 V
12,0 V
13,4 V
Utkoblingsspenning
14,5 V
13,8 V
14,6 V
Utkoblingsstrøm
- EFOY COMFORT
80/140
- EFOY COMFORT 210
2,0 A
4,0 A
1,0 A
4,0 A
10,0 A
10,0 A
Absorpsjonstid
180 min
0 min
300 min
Max. charge time
24 h
2 h
120 h
Altitude up to
1500 m
0 m
2000 m