User manual

Specifications
English
6 Specifications
Performance data
Product
EFOY
COMFORT 80
EFOY
COMFORT 140
EFOY
COMFORT 210
Max. charge capacity
960 Wh/day
80 Ah/day
1728 Wh/day
144 Ah/day
2520 Wh/day
210 Ah/day
Max. nominal power
1
40 W
72 W
105 W
Expected nominal
power at 3000h
1
30 W
60 W
85 W
Max. charging
current at 12 V
3.3 A
6.0 A
8.8 A
Nominal voltage
12 V
Switch-on voltage
2
< 12.3 V
Cut-off threshold
2
> 14.2 V
Required starting
voltage
9 V
Quiescent power
consumption
15 mA
Methanol
consumption
0.9 l/kWh
(0,24 US gal/kWh)
Recommended
batteries
3
12 V lead batteries
(lead acid, lead gel, AGM or LiFePO4)
40 - 160 Ah
60 - 250 Ah
80 - 350 Ah
Recommended for
the following energy
requirements/day
Up to 60 Ah
Up to 115 Ah
Up to 180 Ah
1
The nominal power varies by +/- 10%, decreases with the operating hours.
2
Factory default can be changed via the operating panel (expert mode).
3
The default values are the optimal values preset ex works. If the battery capacities differ sig-
nificantly, please contact your specialist dealer.