User manual
Errors and solutions
Page 101
English
Error message on the
display
Error
code
Solution
Interruption:
Device frozen. Please
defrost device slowly
for at least 24h at room
temperature.
40
The device was exposed to tem-
peratures below 1°C/34°F with-
out a connected battery and/or
an EFOY fuel cartridge that was
not filled sufficiently. It must be
allowed to defrost for approx. 24
hours at room temperature.
Interruption: Sur-
roundings too warm.
Please wait for the de-
vice to cool down.
41
The ambient temperature is too
high. The device will start auto-
matically if the temperature
drops to below 40°C/104°F.
Battery voltage low.
Please check battery
connection and load
battery.
50
52
Please check the cabling and
fuses, and check whether a suit-
able battery is connected. Check
the battery voltage. If it is too
low, please load the battery with
a battery charger. Please also
check other loading devices for
defects, e.g. alternator or charge
controller.
Battery voltage high. If
applicable, please
check additional charg-
ing devices.
51
53
Please check the cabling and
fuses, and check whether a suit-
able battery is connected. Please
also check other loading devices
for defects, e.g. alternator or
charge controller.
Error message on the
display
Error
code
Solution