Switch-off voltage
If the battery voltage reaches the set level, the
EFOY COMFORT fuel cell switches off, provided that
the value set for the "Maintenance charge" param-
eter has also been reached.
Please note your battery's end-of-charging voltage.
Note the charging recommendations provided by
the battery manufacturer.
You can find the permitted value range for the
switch-off voltage in the table on page 87.
Switch-off current
The EFOY COMFORT fuel cell switches off if the
current drops below the set switch-off current
after reaching the switch-off voltage.
If you want the battery voltage to serve as the only
switch-off parameter, set the maximum value, as
the current is always below this value in EFOY
COMFORT fuel cells.
You can find the permitted value range for the
maintenance charge in the table on page 87.
Absorption time
This function serves as an additional switch-off cri-
terion for EFOY COMFORT fuel cells if the switch-
off current is not reached within the set time peri-
od.
You can find the permitted value range for the ab-
sorption time in the table on page 87.