User manual
Operation
Page 88
English
- EFOY COMFORT
80/140
- EFOY COMFORT
210
2.0 A
4.0 A
1.0 A
4.0 A
10.0 A
10.0 A
Absorption time
180 min
0 min
300 min
Max. charge time
24 h
2 h
120 h
Min. charge time
30 min
30 min
180 min
Altitude up to
1500 m
0 m
2000 m
Permitted value
ranges for battery
parameters EFOY
GO!
Factory
defaults
Min.
Max.
User-
defined
value:
Switch-on delay
60 s
2 s
300 s
Switch-on voltage
12.4 V
12.0 V
13.4 V
Switch-off voltage
14.4 V
13.8 V
14.6 V
Switch-off current
- 80i
- 140i
- 210i
2.0 A
2.0 A
4.0 A
0.5 A
1.0 A
2.0 A
10.0 A
10.0 A
10.0 A
Absorption time
60 min
0 min
300 min
Max. charge time
24 h
2 h
120 h
Min. charge time
30 min
30 min
180 min
Altitude up to
2000 m
0 m
2000 m