User manual

Operation
Page 77
English
The device operates independently of the switch-on threshold, and charg-
es the battery until the cut-off threshold is reached.
Please note: The EFOY COMFORT fuel cell can only start if it is connected
to an intact battery and a filled fuel cartridge. The EFOY COMFORT fuel
cell does not switch on if the battery is damaged or has been deeply dis-
charged.
INFO:
If the device fails to start, check that the cover lid is not still attached to
the exhaust hose connector. Remove the cover lid.
3.4.3 Manual Off
1. Press on the operating panel, or select
"Operating mode" in the main menu. The
operating mode selection appears.
2. Select the
"Manual Off" operating mode.
3. Press [ok] to confirm your selection.
4. Wait until the shutdown procedure has
finished and "Shutdown procedure" is no
longer displayed on the info screen.
INFO:
To protect the components, the device should not be switched off until it
has been running for at least 30 minutes since it was started. If the device
is switched off before this period has elapsed, it will continue running for
the remainder of the required running time. The message "Shutdown
procedure" is shown on the display. Do not disconnect the fuel cartridge
or battery during the shutdown procedure.
INFO:
The battery protection and automatic antifreeze functions remain active
after the device is switched off.