User manual

Operation
English
The battery protection function provides deep discharge protection for the
battery, even when the fuel cell is switched off and the charging function
does not take over.
You can select the following menu options in the
"Battery protection" menu:
- Switch-on voltage
- Enable/Disable
- Factory defaults
This option allows you to undo all the battery
protection settings. Press [ok] to confirm or
[] to cancel.
CAUTION!
Incorrectly set operating parameters may damage the battery. This may
nullify your warranty.
Please only use the precise values permitted for the battery parameter
and battery protection settings.
CAUTION!
If you stop protective charging manually, battery protection is disabled
until the next time the fuel cell is started. Deep discharge may damage
your battery.
Permitted value ranges
for switch-on voltage
lead-acid, gel, AGM bat-
teries and EFOY GO!
Factory
defaults
Min.
Max.
User-
defined
value:
Battery protection
(12 V)
11.2 V
10.5 V
12.0 V
Permitted value ranges
for switch-on voltage
LiFePO4 Batteries
Factory
defaults
Min.
Max.
User-
defined
value:
Battery protection
(12 V)
11 V
10.5 V
12.5 V