User manual
Operation 
Page 91 
English 
Maximum charge time 
If the switch-off criteria, voltage and current, have 
not been satisfied, the EFOY COMFORT will shut 
down after defined operating hours. Once the 
switch-on criteria have been satisfied, the EFOY 
COMFORT unit will turn on again, which can be im-
mediately after the maximum charge time. 
This switch-off criterion prevents unlimited charge 
cycles caused by various factors like defective bat-
teries. 
Minimum charge time 
The EFOY COMFORT fuel cell calculates the aver-
age duration of a charging cycle. If this duration 
drops below the preset value, it indicates the error, 
too old, defective or battery too small. This can 
equally be an indication that incorrect battery pa-
rameters have been selected. A warning is dis-
played on the operating panel. Several short charg-
ing cycles can damage the EFOY COMFORT fuel cell 
and/or the battery. Please contact your local dealer 
to solve the problem. 
Altitude up to 
The EFOY COMFORT fuel cell is set by default for a 
use up to an altitude of 1500 meter. For use at a 
higher altitude for a longer period, we recommend 
to increase the value. 
3.7.3.3  Battery protection 
The EFOY COMFORT fuel cell has automatic battery protection, even when 
the EFOY COMFORT fuel cell is switched off. By default, battery protection 
switches on when the battery voltage drops below 11.2 V (lead-acid bat-
teries for min. 60 seconds). 