- Siemens Cordless Telephone User Manual

Servo control
3.4 Torque-controlled operation
Drive Functions
70 Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
HJS
>@

S>&@

S>&@
S>&@
U



Figure 3-6 Torque setpoint
3. Activate enable signals
OFF responses
OFF1 and p1300 = 23
Reaction as for OFF2
OFF1, p1501 = "1" signal and p1300 ≠ 23
No separate braking response; the braking response takes place by a drive that
specifies the torque.
The pulses are suppressed when the brake application time (p1217) expires. Standstill
is detected when the actual speed value is less than the speed threshold (p1226) or
when the monitoring time (p1227) that started when speed setpoint ≤ speed threshold
(p1226) has expired.
Power-on disable is activated.
OFF2
Immediate pulse suppression, the drive coasts to standstill.
The motor brake (if parameterized) is closed immediately.
Power-on disable is activated.
OFF3
Switch to speed-controlled operation
n_set = 0 is input immediately to brake the drive along the OFF3 deceleration ramp
(p1135).
When zero speed is detected, the motor brake (if parameterized) is closed.
The pulses are suppressed when the motor brake application time (p1217) has
elapsed. Standstill is detected when the actual speed value is less than the speed
threshold (p1226) or when the monitoring time (p1227) that started when speed
setpoint ≤ speed threshold (p1226) has expired.
Power-on disable is activated.