- Siemens Cordless Telephone User Manual

Servo control
3.2 Speed setpoint filter
Drive Functions
66 Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
3.2 Speed setpoint filter
The two speed setpoint filters are identical in structure and can be used as follows:
Bandstop
Low-pass 1st order (PT1) or
Low-pass 2nd order (PT2)
Both filters are activated via parameter p1414.x. Parameters p1415 and p1421 are used to
select the filter elements.
'HQRPLQDWRUGDPSLQJ'HQRPLQDWRUQDWXUDOIUHT
S[[[[ WLPHFRQVWDQW
VWRUGHUGHOD\
/RZSDVV37
QG2UGHUILOWHU
I
'HQRPLQDWRUGDPSLQJ
'HQRPLQDWRUQDWXUDOIUHT
1XPHUDWRUQDWXUDOIUHT
/RZSDVV37%DQGVWRS
1XPHUDWRUGDPSLQJ
'
IQ
_\_
I
[
\
S[[[[
'BQ
S[[[[
IQBQ
S[[[[
\
W
IB%
IV
_\_
'BQ
S[[[[
IQBQ
S[[[[
S[[[[
S[[[[
IQB]
\
'B]
Figure 3-2 Filter overview for speed setpoint filters
Function diagrams (see SINAMICS S List Manual)
5020 Speed setpoint filter and speed pre-control
Overview of key parameters (see SINAMICS S List Manual)
Adjustable parameters
p1414[DDS] Speed setpoint filter activation
p1415[DDS] Speed setpoint filter 1 type
p1416[DDS] Speed setpoint filter 1 time constant
p1417[DDS] Speed setpoint filter 1 denominator natural frequency
p1418[DDS] Speed setpoint filter 1 denominator damping
p1419[DDS] Speed setpoint filter 1 numerator natural frequency
p1420[DDS] Speed setpoint filter 1 numerator damping
p1421[DDS] Speed setpoint filter 2 type
p1422[DDS] Speed setpoint filter 2 time constant
p1423[DDS] Speed setpoint filter 2 denominator natural frequency
p1424[DDS] Speed setpoint filter 2 denominator damping