Basic information about the drive system
12.11 Notes on the number of controllable drives
Drive Functions
522 Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Servo control
Servo without extra function modules (e.g. setpoint channel):
PROFIBUS-DP cycle >=1 ms
6 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which
max. 2 induction motors or
2 drives (sampling times: current controller 62.5 µs / speed controller 62.5 µs), both
also induction motors
6 motor measuring systems
3 direct measuring systems
1 Terminal Module TM31 or 1 Terminal Board TB30 with 1 ms sampling time
1 Active Line Module with 250 µs sampling time without Voltage Sensing Module
Servo without extra function modules (e.g. setpoint channel):
PROFIBUS-DP cycle >= 500 µs and < 1 ms, valid for integrated SINAMICS drives for
SIMOTION and SINUMERIK
5 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which
max. 2 induction motors or
2 drives (sampling times: current controller 62.5 µs / speed controller 62.5 µs), both
also induction motors
Remaining modules as above
Servo with CBE20 function module:
PROFINET-IO bus cycle time > = 1 ms
5 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which
max. 2 induction motors or
1 drive (sampling times: current controller 62.5 µs / speed controller 62.5 µs),
induction motor also possible
5 motor measuring systems
2 direct measuring systems
1 Terminal Module TM31 or 1 Terminal Board TB30 with 1 ms sampling time
1 Active Line Module with 250 µs sampling time without Voltage Sensing Module
Servo with CBE20 function module:
PROFINET-IO bus cycle time > = 500 µs and < 1 ms
4 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which
max. 2 induction motors or
1 drive (sampling times: current controller 62.5 µs / speed controller 62.5 µs),
induction motor also possible
Remaining modules as above
Servo with EPOS function module
3 drives (sampling times: current controller 125 µs / speed controller 125 µs / position
controller 1 ms / positioning 4 ms)
3 motor measuring systems
1 Active Line Module with 250 µs sampling time without Voltage Sensing Module