- Siemens Cordless Telephone User Manual

Basic information about the drive system
12.5 Inputs/outputs
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
487
Bidirectional digital inputs/outputs
',
'2
9
;
','2;
S
;
;
0
0
9
9
U
U
;
0
;
0
S
S
U
U
S
S
Figure 12-11 Bidirectional inputs/outputs: signal processing using DI/DO 0 of CU320 as an example
Properties
Can be parameterized as digital input or output.
When set as digital input:
Six "high-speed inputs" on Control Unit 320
If these inputs are used, for example, for the "flying measurement" function, they act
as "high-speed inputs" with virtually no time delay when the actual value is saved.
The properties of the "pure" digital outputs apply.
When set as digital output:
The properties of the "pure" digital outputs apply.
Function diagrams (see SINAMICS S List Manual)
2030 Bidirectional digital inputs/outputs (DI/DO 8 ... DI/DO 9)
2031 Bidirectional digital inputs/outputs (DI/DO 10 ... DI/DO 11)
2130 Bidirectional digital inputs/outputs (DI/DO 8 and DI/DO 9)
2131 Bidirectional digital inputs/outputs (DI/DO 10 and DI/DO 11)
2132 Bidirectional digital inputs/outputs (DI/DO 12 and DI/DO 13)
2133 Bidirectional digital inputs/outputs (DI/DO 14 and DI/DO 5)
9400 Bidirectional digital inputs/outputs (DI/DO 0 ... DI/DO 7)
9401 Bidirectional digital inputs/outputs (DI/DO 8 ... DI/DO 15)
9402 Bidirectional digital inputs/outputs (DI/DO 16 ... DI/DO 23)
9560 Bidirectional digital inputs/outputs (DI/DO8 and DI/DO 9)