Basic information about the drive system
12.4 BICO technology: interconnecting signals
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
483
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
p2900[0...n] CO: Fixed value_%_1
p2901[0...n] CO: Fixed value_%_2
p2930[0...n] CO: Fixed value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.
12.4.7 Scaling
Signals for the analog outputs
Table 12-5 List of signals for analog outputs
Signal Parameter Unit Normalization
(100 % = ...)
Speed setpoint before the setpoint
filter
r0060 RPM p2000
Speed actual value motor encoder r0061 RPM p2000
Actual speed r0063 RPM p2000
Drive output frequency r0066 Hz Reference frequency
Absolute current actual value r0068 Aeff p2002
Actual DC link voltage value r0070 V p2001
Total torque setpoint r0079 Nm p2003
Actual active power r0082 kW r2004
Control deviation r0064 RPM p2000
Modulation depth r0074 % Reference control factor
Current setpoint, torque-generating r0077 A p2002
Current actual value, torque-
generating
r0078 A p2002
Flux setpoint r0083 % Reference flux
Flux actual value r0084 % Reference flux
Speed controller
PI torque output
r1480 Nm p2003
Speed controller
I torque output
r1482 Nm p2003