Infeed
1.2 Smart Infeed
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
33
Note
In a supply system without regenerative feedback capability (e.g. generators), regenerative
operation must be inhibited via the binector input p3533.
Function diagrams (see SINAMICS S List Manual)
1775 Overviews - Smart Infeed
8820 Control word sequential control infeed
8826 Status word sequential control infeed
8828 Status word infeed
8832 Processor
8834 Missing enables, line contactor control
8850 Interface to the Smart Infeed (control signals, actual values)
8860 Supply voltage monitoring
8864 Power frequency and Vdc monitoring
Overview of key parameters (see SINAMICS S List Manual)
r0002 Infeed/operating display
r0046 CO/BO: Infeed missing enable signals
p0210 Device supply voltage
p0840 BI: ON/OFF1
p0844 BI: 1. OFF2
p0852 BI: Enable operation
r0898 CO/BO: Control word sequential control infeed
r0899 CO/BO: Status word sequence control infeed
r2138 CO/BO: Control word, faults/alarms
r2139 CO/BO: Status word, faults/alarms 1
r3405 CO/BO: Status word infeed
p3533 BI: Infeed, inhibit regenerative operation
1.2.2 Line supply and DC link identification routine for Smart Infeed Booksize
The characteristic line supply and DC link quantities are determined using the automatic
parameter identification routine. They provide the basis to optimally set the controllers in the