Function modules
7.9 Basic positioner
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
259
p2581 CO: EPOS software limit switch, plus
p2582 BI: EPOS software limit switch activation
r2683 CO/BO: EPOS status word 1
STOP cam
p2568 BI: EPOS STOP cam activation
p2569 BI: EPOS STOP cam, minus
p2570 BI: EPOS STOP cam, plus
r2684 CO/BO: EPOS status word 2
7.9.3 Referencing
Features
Reference point offset (p2600)
Reversing cams (p2613, p2614)
Reference cam (p2612)
Binector input start (p2595)
Binector input setting (p2596)
Velocity override (p2646)
Reference point coordinate (p2598, p2599)
Selecting the referencing type (p2597)
Absolute encoder adjustment (p2507)
NOTICE
Referencing distance-coded zero marks is not supported.
Description
After a machine has been powered-up, for positioning, the absolute dimension reference
must be established to the machine zero. This operation is known as referencing.
The following referencing types are possible:
Setting the reference point (all encoder types)
Incremental encoder
Active referencing (reference point approach (p2597 = 0)):
Reference cams and encoder zero mark (p2607 = 1)
Encoder zero mark (p0495 = 0)
External zero mark (p0495 ≠ 0)