- Siemens Cordless Telephone User Manual

Function modules
7.7 Extended torque control (kT estimator, Servo)
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
235
Function diagrams (see SINAMICS S List Manual)
9794 Cooling unit, control and feedback signals
9795 Cooling unit sequence control
Overview of key parameters (see SINAMICS S List Manual)
r0046.29 Missing enable signals - cooling unit ready missing
p0192.06 Power unit firmware properties - water cooling
r0204.06 Power unit hardware properties - water cooling
p0260 Cooling unit, starting time 1
p0261 Cooling unit, starting time 2
p0262 Cooling unit fault conductivity delay time
p0263 Cooling unit fault water flow delay time
p0264 Cooling unit, run-on time
r0265 BO: Cooling unit control word
p0266[0...7] BI: Cooling unit signal source feedback signals
r0267 BO: Cooling unit status word display
7.7 Extended torque control (kT estimator, Servo)
Description
The "extended torque control" function module comprises two modules - the k
T
estimator and
the compensation of the voltage emulation error of the drive converter. This allows the
torque accuracy to be increased.
Note
When this function module is activated, the maximum number of drives that can be
controlled from a Control Unit is reduced by at least one drive.
Features
k
T
estimator (only for synchronous motors)
Compensation of the voltage emulation error of the drive converter (p1952, p1953)
Configuration via p1780
Commissioning via STARTER
The extended torque control can be activated via: Right-click the drive > Properties >
Function Modules.