- Siemens Cordless Telephone User Manual

Function modules
7.4 Extended brake control
Drive Functions
228 Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
speed controller is immediately enabled - the speed setpoint is enabled after the brake
opening time (p1216). When the master switch is in the zero position, the speed setpoint is
inhibited - the drive is ramp-down using the ramp function generator. The brake closes once
the standstill limit (p1226) has been fallen below. After the brake closing time (p1217), the
speed controller is inhibited (the motor is no longer generating any force). The extended
brake control is used with the modifications described below.
> @
> @
[ ]
1
r1229.10
p1279[0]
p1279[1]
r12 29.3
<1>
p1275.02 (1)
1
0
1
p1224[0]
<1>
r0898.6
&
p1142[C]
(r0899.15)
p1152
<1>
[2501 ]
p0856
3XOVHHQDEOH
H[WEUDNHFRQWURO
25ORJLFRSHUDWLRQ
%UDNH
25ORJLFRSHUDWLRQ
UHVXOW
(QDEOHVSHHGFRQWUROOHU
(QDEOHQBVHW
6HWSRLQWHQDEOH
(QDEOHVSHHGVHWSRLQW
%UDNHWRVWDQGVW
!6HWSRLQWHQDEOHIURPKLJKHUOHYHO
FRQWUROOHUHJ6
 (QDEOHVHWSRLQW
0DVWHUVZLWFKPRYHG
>[[[[@)XQFWLRQGLDJUDPQXPEHU
Figure 7-4 Example, operating brake for a crane drive
7.4.5 Integration
The extended brake control function is integrated in the system as follows.
Function diagrams (see SINAMICS S List Manual)
2704 Zero speed detection (r0108.14 = 1)
2707 Releasing/applying brake (r0108.14 = 1)
2711 Signal outputs (r0108.14 = 1)
Overview of key parameters (see SINAMICS S List Manual)
r0108.14 Extended brake control
r0899 CO/BO: Status word sequence control