- Siemens Cordless Telephone User Manual

Basic functions
6.8 Armature short-circuit brake, internal voltage protection, DC brake
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
197
Function diagrams (see SINAMICS S List Manual)
7014 External armature short circuit (p0300 = 2xx or 4xx, synchronous motors)
7016 Internal armature short circuit (p0300 = 2xx or 4xx, synchronous motors)
7017 DC brake (p0300 = 1xx, induction motors)
Overview of key parameters (see SINAMICS S List Manual)
p1226 Standstill detection, velocity threshold
p1230[0..n] BI: Armature short-circuit/DC brake activation
p1231[0..n] Armature short-circuit/DC brake configuration
p1232[0..n] DC braking, braking current
p1233[0..n] DC braking time
p1234[0..n] Speed at the start of DC braking
p1235[0..n] BI: External armature short-circuit, contactor feedback signal
p1236[0..n] External armature short-circuit, contactor feedback signal monitoring time
p1237[0..n] External armature short-circuit, waiting time when opening
r1238 CO: Armature short-circuit, external state
r1239.0..10 CO/BO: Armature short-circuit/DC brake status word