Vector control
4.12 Motor data identification and rotating measurement
Drive Functions
144 Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
DANGER
During speed controller optimization, the drive triggers movements in the motor that can
reach the maximum motor speed. The emergency STOP functions must be fully
operational during commissioning. To protect the machines and personnel, the relevant
safety regulations must be observed.
Note
If speed control optimization is used for operation with encoder, then the control operating
mode is automatically reset to speed control without encoder, so that the encoder test
can be carried out.
Overview of key parameters (see SINAMICS S List Manual)
r0047 Status identification
p1300[0...n] Open-loop/closed-loop control operating mode
p1900 Motor data identification and rotating measurement
r3925 Identification completion display
r3927 MotId control word
r3928 Rotating measurement configuration
Rotating measurement
p0391 Current controller adaptation starting point Kp
p0392 Current controller adaptation starting point Kp adapted
p0393 Current controller adaptation P gain scaling
p1959 Speed controller optimization configuration
p1960 Rotating measurement selection
p1961 Saturation characteristic speed for calculation
p1965 Speed controller optimization speed
p1967 Speed controller optimization dynamics factor
r1968 Speed controller optimization dynamic factor current
r1969 Speed controller optimization inertia identified
r1973 Speed controller optimization encoder test pulse number determined
p1980 Pole position identification technique
p1990 Encoder adjustment selection
Motor data identification at standstill
p1909[0...n] Motor data identification control word
p1910 Motor data identification selection