Vector control
4.8 Torque limiting
Drive Functions
132 Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
4.8 Torque limiting
Description
S
0D[
0LQ
S
U
U
S
S
S
U
U
U
U
7RUTXH
OLPLWV
3RZHU
OLPLWV
&XUUHQWOLPLW
Figure 4-12 Torque limiting
The value specifies the maximum permissible torque whereby different limits can be
parameterized for motor and regenerative mode.
p0640[0...n] Current limit
p1520[0...n] CO: Torque limit, upper/motoring
p1521[0...n] CO: Torque limit, lower/regenerative
p1522[0...n] CI: Torque limit, upper/motoring
p1523[0...n] CI: Torque limit, lower/regenerative
p1524[0...n] CO: Torque limit, upper/motoring, scaling
p1525[0...n] CO: Torque limit, lower/regenerating scaling
p1530[0...n] Motor mode power limit
p1531[0...n] Regenerative mode power limit
The current active torque limit values are displayed in the following parameters:
r0067 Maximum drive output current
r1526 Torque limit, upper/motoring without offset
r1527 Torque limit, lower/regenerative without offset
The following limits all apply to the torque setpoint, which is present either at the speed
controller output in the case of speed control, or at the torque input in the case of torque
control. The minimum/maximum value of the different limits is used in each case. The
minimum value is calculated cyclically and displayed in parameters r1538 and r1539.
r1538 CO: Upper effective torque limit
r1539 CO: Lower effective torque limit
These cyclical values therefore limit the torque setpoint at the speed controller
output/torque input or indicate the instantaneous max. possible torque. If the torque