Catalog 2009/01 Germany International Head Quarter, Sales Department: Sales Department, Service Austria: EFFEKTA Regeltechnik GmbH Rheinwaldstr. 34 D-78628 Rottweil Tel.: +49 741 17451 0 Fax: +49 741 17451 22 E-Mail: info@effekta.com URL: www.effekta.com EFFEKTA Regeltechnik GmbH Industriestraße 4 A-3910 Zwettl, Austria Tel.: +43 2822 200 18 10 Fax: +43 2822 200 18 20 E-Mail: sales@effekta.at URL: www.effekta.at Sales Department North: Production Hungary: EFFEKTA Regeltechnik GmbH Falkenberger Str.
Imprint This catalog is a publication of Effekta Regeltechnik GmbH Rheinwaldstr. 34 D-78628 Rottweil Tel.: +49 741 17451 0 Fax.: +49 741 17451 22 E-Mail: info@effekta.com URL: www.effekta.com Management: P. Androt, G. Kremer, R. Schmeh Standards, specifications and designs could be changed without any announcements. There is no responsibility from Effekta® against mistakes in this brochure. All trademarks belong to the original owners.
Table of contents Table of contents Index Category Index Page Business Company Chronology / Array of products 2-3 UPS classification UPS classification / Technology 4-5 AC line-interactive UPS 400-3200VA ME series 6-7 MI-RM series 8-9 MT series 10-11 MT-RM series 12-13 MH series 14-15 MH-RM series 16-17 MKD series 18-19 MKD-RM series 20-21 MH 6000 22-23 MH 6000 RM 24-25 MHD 10-20kVA 26-27 Zephyr 28-29 Quasar 10-40kVA 30-31 Quasar 60-120kVA 32-33 Pegasus 10-40kVA 34-3
Power Supplies Business Company Company Business Chronology & development: - Foundations: HJ Elektronik in 1984 EFFEKTA® Regeltechnik GmbH in 1990 EFFEKTA® (Taiwan) in1991 EFFEKTA® (Hungary) in 1998 Rottweil sales department in 1999 Amalgamation of business of Tettnang and Rottweil in Rheinwaldstraße 34, Rottweil in 2007 . . . . . . - Management-buy-out in 2000 with new directors: P. Androt, G. Kremer and R. Schmeh - Today: the company employs 62 staff.
Business Company USV-Systems Pegasus 10-40 kVA Pegasus 60-160 kVA Pegasus 200-300 kVA (from left to right) Most UPSs are employed to safeguard data processing functions in case of power disturbances. EFFEKTA UPSs are not only suited to use with computers, but also with all sensitive, power-dependent units. ® The EFFEKTA range provides a solution for every kind of application we have got a solution. We are also experienced in custom designs and small production runs.
Power Supplies UPS classification UPS classification Power disturbance Usable UPS class VFI VI VFD Power failure >10ms Voltage fluctuations <16 ms Peaks 4-16ms Over-voltage Lightning effects Surge <4ms Two differenr technologies are used to provide a consumer with uninterrupted power. The norms EN 50091-3 and IEC 62040-3 serve to differentiate the two technologies and assess their protection.
UPS classification Input Manual Bypass (Option) Filter Bidirectional Inverter Charger Rectifier Inverter Input Output Output Battery Charger Battery Automatic Bypass LINE INTERACTIVE Online Double-Conversion Line-interactive systems (VI) Online double-conversion (VFI) . Short transfer time . Bi-directional inverter . Output voltage mostly pure sine wave / . Securest UPS technology . Protection against all types of disruption . Stable output voltage . No transform time . Bypass function . .
Power Supplies ME ME Line-interactive 400, 500, 600, 650, 800, 1000, 1500VA The ME series offers as a succession model of the proven MI series reliable protection before current failures. It was technically optimised and delivers optimum protection and improved communication possibilities for the electronic data processing with its digital circuit. As a reasonable line-interactive model it is suitably for the application on pc’s, workstations and network components.
AC line-interactive UPS 400-3200VA Rear view of ME 400-800VA Models with USB Rear view of ME 1000/1500 Rear view of ME 400-800VA Models with RS232 Specifications Specifications Model Input Output (AC-Mode) Voltage (VAC) Frequency (Hz) Synchronous zone AVR Regulation Output (INV.mode) Voltage Battery Frequency Waveform Capacity (VA/W) Transfer time (ms) Autonomy at full load in min.
Power Supplies MI RM RM MI Line-interactive 600-1200VA MI-Series is a cost-effective line-interactive system, that protects sensitive consumers from power blackouts. Areas of application are computers and smaller servers and especially active network components in 19” switchboards.
AC line-interactive UPS 400-3200VA MI 600 RM (rear view) MI 1200 RM (rear view) Specifications Specifications Type Output Power VA/Watt Max current at 230 V (ampere) Sockets Output voltage Frequency Waveform Transfer time Input Voltage Frequency Boost (+13%) Buck (-13%) Batteries Full load DC voltage Accumulators Type Recharge time Efficiency AC-AC Auto-restart Audible noise Display LED (UPS Status) Acoustic alert Protection Overload Lightning EMC/LVD Certificates and tests Communication Environment Temp
Power Supplies MT MT Line-Interactive 700, 1000, 1500, 2000, 3200VA The MT Series is a progressive line-interactive UPS, that protects sensitive consumers from power blackouts, spikes and other disruptions. Areas of application are computers, remote telecommunications and other com puter-aided systems. The unit’s compact and stable con struction provides additional security and flexibility of use.
AC line-interactive UPS 400-3200VA MT 700 (rear view) MT 1000-2000 (rear view) MT 3200 (rear view) Specifications Specifications Type Output Power VA/Watt Max current at 230 V (ampere) Sockets Output voltage Frequency Waveform Input Voltage Frequency Boost (+13%) Buck (-13%) Batteries Full load DC voltage Accumulators Type Recharge time Test Efficiency AC-AC DC-start-up (black-start) Auto-restart Overload Audible noise LED display UPS status Acoustic alert Protection Overload Lightning EMC/LVD Certifica
Power Supplies MT RM RM MT Line-interactive 700, 1000, 1500, 2000, 3200VA The MT Series is a progressive line-interactive UPS, that protects sensitive consumers from power blackouts, spikes and other disruptions. Areas of application are computers, remote telecommunications and other computer-aided systems. The enclosures of the MT Series are almost the most robust and compact racks on the UPS market (starting from a 300mm mounting depth).
AC line-interactive UPS 400-3200VA MT 700-1500 RM (rear view) MT 2000 RM (rear view) MT 3200 RM (rear view) Specifications Specifications Type Output Power VA/Watt Max current at 230V (ampere) Sockets Output voltage Frequency Waveform Input Voltage Frequency Boost (+13%) Buck (-13%) Batteries Full load DC voltage Accumulators Type Recharge time Test Efficiency AC-AC DC-start-up (black-start) Auto-Restart Overload Audible noise LED display UPS status Acoustic alert Protection Overload Lightning EMC/LVD C
Power Supplies MH MH Online double-conversion 700, 1000, 1500, 2000, 3000 VA ‧‧ ‧‧ The MH Series is a state of the art, microprocessorcontrolled online double-conversion UPS solution with an electronic bypass for supersensitive and critical applications such as servers, workstations, and measuring or industrial machines.
AC online double-conversion UPS 700-3000VA MH 700-1500 (rear view) MH 2000-3000 (rear view) Specifications Specifications Type Output Power VA/Watt Max current at 230 V Sockets Output voltage Frequency Waveform Input Voltage Frequency Batteries Full load DC-voltage Accumulators Type Recharge time Test PFC Efficiency AC-AC DC-start-up (black-start) Auto-restart Overload Audible noise LED display USV status Load status Audible alert Protection Overload Lightning EMC/LVD Certificates and tests Communication
Power Supplies MH RM RM MH MH 2000-3000 RM incl. battery cabinet Online double-conversion 19“ 700, 1000, 1500, 2000, 3000VA The MH RM is a state of the art, microprocessor-controlled online double-conversion solution with an electronic bypass for supersensitive and critical application such as servers, workstations and measuring or industrial machines. The enclosures of this series are amongst the most robust and compact racks on the UPS market (starting from a 390mm mounting depth). .
AC online double-conversion UPS 700-3000VA MH 700-1500 RM (rear view) MH 700-1500 RM (front view) MH 2000-3000 RM (with battery cabinet) (rear view) Battery cable Specifications Specifications Type Output Power VA/Watt Max current at 230V Sockets Output voltage Frequency Waveform Input Voltage Fequency Batteries Full load DC voltage Accumulators Type Recharge time Test PFC Efficiency AC-AC DC-start-up (black-start) Auto Restart Overload Audible noise LED display UPS status Load status Audible alert Pro
Power Supplies MKD MKD MKD 1000 To the right: Rear view To the left: Front view Description Features The MKD UPS is a modern, microprocessor controlled online double-conversion UPS. The MKD UPS features electronic bypass and is to be applied with supersensitive and critical applications like servers, workstations, metrological or industrial systems.
AC online double-conversion UPS 700-3000VA Rear view MKD 700/1000 Rear view MKD 2000 Rear view MKD 3000 Specifications Specifications Type Power Autonomy time Input Output Overload Bypass Battery Prot./standards Environment Mechanic Terminals Communication Power in VA Power in W Nominal load Nominal input voltage Input voltage range Input frequency range Max.
Power Supplies MKD-RM MKD-RM Right hand picture: MKD 2000/3000 RM Description Features The MKD UPS is a modern, microprocessor controlled online double-conversion UPS. With its extraordinary compact design MKD RM can specially be used in racks with a minimum of space capacity. ‧‧ The MKD UPS features an electronic bypass and is to be applied with supersensitive and critical applications like servers, workstations, metrological or industrial systems.
AC online double-conversion UPS 700-3000VA Rear view of MKD 700/1000 RM (internal batteries) Rear view of MKD 2000 RM (electronics only) Rear view of MKD 3000 RM (electronics only) Rear view of battery pack for MKD 2000/3000 RM (same type for XL models) Specifications Specifications Type Power Autonomy time Input Output Overload Bypass Battery Prot.
Power Supplies MH 60006000 MH MH 6000 incl battery cabinet Online double-conversion 6000VA with 1-phase input ‧‧ ‧‧ MH 6000 is a progressive development of UPS MH 5000/7000. With its fast DSP (Digital Signal Processing) controller it offers a new sine-wave quality and high performanc in controlling input & output. Digitalisation of all circuits accelerates, optimises and reduces the number of components and increases the standard lifetime of important parts.
AC large UPS 6-300kVA MH 6000 Display MH 6000 (rear view) MH 6000 (adapter slot) Specifications Specifications Type Power VA Rating Wattage Cos phi Input Voltage Frequency Current in Ampere PFC (power-factor-correction) Output Voltage Current in Ampere Overload Frequency Waveform Crest factor Harmonic distortion Fault reaction Efficiency BatterIES Autonomy time (100% load) DC-voltage Number of blocs Capacity per unit Type Expected lifetime Recharge time Bypass (SBS) Nominal voltage Overload Manuel bypas
Power Supplies MH 60006000 RM MH RM 6000VA online double-conversion with single-phase output ‧‧ UPS-classification VFI-SS-111 in accordance with IEC 62040-3 True online double-conversion Digital control processor LCD display, 30 different status messages Sine wave current consumption Pure sine wave output Digital battery management Modular battery extension RS-232 + EPO (equipped as standard) Additional slot for optional relaycard or SNMP-adapter Management software enclosed 24 months’ warranty ‧‧ Opt
AC large UPS 6-300kVA rear view: Electronic-module at top, battery cabinet middle and bottom Specifications Specifications Type Power VA Rating Wattage Cos phi Input Voltage Frequency Current in Ampere PFC (power-factor-correction) Output Voltage Current in Ampere Overload Frequency Waveform Crest factor Harmonic distortion Fault reaction Efficiency BatterIES Autonomy time (100% load) DC-voltage Number of blocs Capacity per unit Type Expected lifetime Recharge time Bypass (SBS) Nominal voltage Overload Man
Power Supplies MHD 10-20kVA MHD 10-20kVA Online double-conversion 10-20kVA with 1-phase (10kVA) input or 3-phase (10, 15, 20kVA) input The MHD 10-20kVA with its fast DSP (Digital Signal Processing) controller offers a new sine-wave quality and high performanc in controlling input & output. Digitalisation of all circuits accelerates, optimises and reduces the number of components and increases the standard lifetime of important parts.
AC large UPS 6-300kVA MHD 10kVA display UPS electronics rear view Specifications Specifications Input Output Battery Transfer Time Indicator Removable Audible Alarm Interface Certificates Environment Weight Dimension Model Capacity Nominal Voltage Voltage Range Frequency Power Factor Voltage Frequency Wave-form Distortion Crest Ratio Type Capacity Back-up Built-In Charger Charger (Option) Charging Voltage Recharger Time AC-DC to Bypass LCD LED Battery Mode Battery Low Overload Fault RS-232 Interface
Power Supplies Zephyr Zephyr True online double-conversion, 10-30kVA, 3-phase input, 1-phase output ‧‧ ‧‧ Zephyr generates a reliable and uninterruptible power line. It is a new true online double-conversion unit with inverters ideally suited to IT and industrial applications. ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ 28 UPS-classification VFI-SS-111 in accordance with IEC 62040-3 Online double-conversion Input power factor 0.
AC large UPS 6-300kVA Specifications Specifications Power (in kVA) 10 15 20 25 30 Autonomy time in min.
Power Supplies Quasar 10-40 Quasar 10-40 True online double-conversion, 10-40kVA, 3-phase input, 3-phase output ‧‧ ‧‧ Quasar generates a reliable and uninterruptible power line. It is a true online double-conversion unit with 100kHz inverters and is ideally suited to most IT and industrial applications. ‧‧ ‧‧ ‧‧ ‧‧ ‧‧ Up to 6 systems can be connected in parallel for redundant operations (n+1operation) or for power increase.
AC large UPS 6-300kVA Specifications Specifications Power (in kVA) 10 15 20 25 30 40 Autonomy time in min. (more info on request) 7 20 35 12 20 30 7 15 20 5 10 15 7 12 18 7 11 14 Type Power Power in kVA / kW Cos phi Input Voltage Frequency Power factor correction Output Voltage Current in ampere Regulation - static Regulation - dynamic (100% load fluct.
Power Supplies Quasar 60-120 60-120 Quasar Online double-conversion, 60-120kVA, with 3-phase input, 3-phase output The UPS Quasar 60-120kVA is a progressive development of UPS Quasar 10-40kVA version. The Quasar enables a reliable and uninterruptible power line. It is a double-conversion unit for supersensitive industrial and IT applications current available. Up to 6 systems can be connected in parallel for redundant operations (n+1operation) or for power increase.
AC large UPS 6-300kVA Specifications Specifications Power (in kVA) 60 80 100 120 Autonomy time in min.
Power Supplies Pegasus 10-40kVA 10-40kVA Pegasus 10-20 kVA 3/1-phase 10-40 kVA 3/3-phase Online double-conversion 10, 15, 20, 30, 40kVA The PEGASUS is a online double-conversion UPS system with 1- or 3-phase output. It can be configured parallel-redundant. Up to 6 Systems can be connected in parallel for redundant operations and increases the availability. The electronic components are up to highest standards as known from military requirements.
AC large UPS 6-300kVA block diagram UPS electronics (modular design / power module) control panel Specifications Specifications Model Power Efficiency % (ECO-Mode) Efficiency (AC-AC) - % (Online-Mode) Input Voltage nominal Voltage tolerance Frequency Power factor Output Voltage Frequency Waveform Distortion Crest factor Batteries Type Capacity Autonomy Voltage nominal Charging voltage Recharging time Transfertime AC-DC to bypass Display LCD LED Acoustic alarm Restable Interface RS-232 interface SNMP (Op
Power Supplies Pegasus 60-160kVA 60-160kVA Pegasus 60, 80, 100, 125, 160kVA 3/3 phase Online double-conversion 60, 80, 100, 125, 160kVA The PEGASUS is a online double-conversion UPS system with 3-phase output. It can be configured parallel-redundant and increases the availability of the power source. The usage of IGBT rectifiers reduces the distortion of dependent mains. The current drain is almost ideal sinus and the power factor was increased in comparison to traditional thyristor design.
AC large UPS 6-300kVA block diagram control panel Specifications Specifications Model Power Efficiency (AC-AC) - % (ECO mode) Efficiency (AC-AC) - % (Online mode) Input Voltage nominal Voltage tolerance Frequency Power factor (@ 400V) Output Voltage Frequency Waveform Output current nominal @ CosPhi 0.8/1.
Power Supplies Pegasus 200-300kVA 200-300kVA Pegasus 200-300 kVA 3/3-phase Online double-conversion 200, 250, 300kVA The PEGASUS is a online double-conversion UPS system with 3-phase output. It can be configured parallel-redundant and increases the availability of the power source. The electronic components are up to highest standards as known from military requirements.So you find an UPS system with enhanced reliability, availability and safety.
AC large UPS 6-300kVA block diagram control panel UPS electronics Specifications Specifications Model Power Efficiency (AC-AC) - % (ECO mode) Efficiency (AC-AC) - % (Online mode) Input Voltage nominal Voltage tolerance Frequency Power factor (@ 400V) Output Voltage Frequency waveform Output current nominal @ CosPhi 0.8/1.
Power Supplies MHD ModularModular MHD Online double-conversion 4-24kVA MHD Modular is a scalable single phase or three-phase double-conversion UPS and can be configured to a capacity of 4kVA, 8kVA, 12kVA, 16kVA, 20kVA, 24kVA with maximum 6 modules. It can be configured to parallel redundancy which provides the maximum reliability. And delivers power output per modules from 4kVA to 24 kVA.
AC large modular UPS 4-24kVA The 4kVA-modules of EFFEKTA® MHD Modular provide advanced UPS technology with high operating efficiency. The System absolutely prevents power failures, power sags, surges, brownouts, line noise, spikes, frequency variations switching transients and harmonic distortion. With its fast DSP-controller (Digital Signal Processing) it offers a highend sinewave-quality and high performance in controlling input & output.
Power Supplies MHD ModularModular MHD LOAD LOAD The MHD Modular is a scalable online double-conversion UPS and with up to 6 modules it can be configured to 4kVA, 8kVA, 12kVA, 16kVA, 20kVA and 24kVA. One of the most important advantages of the modularand redundant design is the improved safety and reliability. If the MHD Modular is configured to N+X parallel- redundancy, the load is instantaneously redistributed among the remaining modules.
AC large modular UPS 4-24kVA Specifications Specifications Number of modulescapacity 1 Module 2 Modules 3 Modules 4 Modules 5 Modules 6 Modules N N+1 (4kVA) N+2 (8kVA) N+3 (12kVA) N+4 (16kVA) N+5 (20kVA) N N+1 (4kVA) N+2 (8kVA) N+3 (12kVA) N+4 (16kVA) N N+1 (4kVA) N+2 (8kVA) N+3 (12kVA) N N+1 (4kVA) N+2 (8kVA) N N+1 (4kVA) 4kVA 8kVA 12kVA 16kVA 20kVA N 24kVA Model Capcity Input Output Singel / three phase Wiring Voltage Input frequency Power factor Bypass Phase Wiring Voltag
Power Supplies Software Software for all EFFEKTA® AC UPSs (400VA-300kVA) The UPS management software solution PowerShut Plus runs as a client/server application for heterogeneous networks or local computers. It works on Windows 95/98/2000/NT/XP/Vista (Business and higher), Novell, Linux and all current Unix derivatives. It also includes an SNMP agent for Windows NT and Novell. All Servers on the network can be shut down via RCCMD (MultiserverShutdown).
UPS management Line fail UPSMON module (right-hand images) . Monitoring of all UPSs connected via UPSMAN/SNMP adapter . Remote network control of all UPS . Graphical representation of UPS input data (current, voltage) . Reading and display UPSMAN event log files . Programming UPSMAN scheduler . Graphical interface with all UPS information . Graphical interface on UNIX, MAC, VMS (JAVAMON) Normal operation UPSMAN configuration UPSMAN module (right-hand images) .
Power Supplies SNMP SNMP for all EFFEKTA® AC UPSs (400VA-300kVA) CS 121 SNMP adapter . Powerful 32-bit RISC processor, 8MB RAM, 4MB Flash The CS121 is equipped with a 32-bit processor, 8 MB RAM, 4 MB Flash, 2 serial interfaces and a 10/100MBIT network connection. COM1 is provided for communication with the UPS, COM2 may be used for configuring the adapter, connection to a modem or to forwarding UPS data to other computers.
UPS management Configuration and monitoring via web browser UNMS (9 UPSs) UPSMAN module UNMS UPS monitoring panel (freeware) Available for Windows 95/ 98/ ME/ NT/ 2000 / XP / Vista (Business and higher) Clear representation of all network UPS Up to 9 UPS in network can be monitored (freeware version) Simple configuration Number of connections adjustable Acoustic alert Expandable on request SNMP adapter support Up to 1500 nodes optional . UPS monitoring via floating contacts . . . . . . .
Power Supplies External bypass External bypass An external bypass can be used to guarantee optimum availability of the EFFEKTA®’ UPS systems, particulary for critical applications. During UPS maintenance, the bypass bridge the UPS and provides the load with uninterrupted power after a manual changeover. Type Adaptable up to (UPS power in kVA) Socket Mounting/construction Type Adaptable up to (UPS power in kVA) Socket Mounting/construction Further models on request.
UPS accessories Battery cabinets cabinets Battery B10 Battery cabinet for UPSs in office premises Steel cabinet with synthetic front (IP 20) Article B10/… B10/… Dimensions (H x W x D in mm) 207x140x437 207x140x437 Adapted battery type BFR/BT12-7 BFR/BT12-9.5 Max. number of batteries 8 8 B28 Battery cabinet for small and medium UPS types. Lacquered steel construction (black / IP20) on casters. Optionally with BACS incl. LCD Display.
Power Supplies P-Bank EFFEKTA P-Bank Portable Battery Bank The EFFEKTA® P-Bank is your perfect mobile power supply for most mobile devices with a DC input of maximum 19V / 3.5A. Simply connect the P-Bank to your laptop, mobile DVD player, digital camera, camcorder, portable CD player, PDA, mobile phone, GPS unit or other portable device to prolong its operating time. In addition to powering your devices, the P-Bank will charge their internal batteries at the same time.
Mobile DC power supply 3 4 Left hand Image: Scope of delivery of the P-Bank 1. Battery 2. Leather case 3. Power supply (AC input 100~240V, DC output 19V/ 3.2A) 4. Output cable 5. DC plug adapters (8 pcs.
Power Supplies BT batteries BT batteries BT 12-28 BT 12-18 Our long-standing experience with emergency power systems and uninterruptible power supply units is our guarantee for the highest quality and reliability of EFFEKTA® batteries. BT batteries are ideally suited for use in: . Uninterruptible power supplies (UPSs) . Telecommunications systems . Fire alarm and safety systems . Medical equipment . Photovoltaic applications Advantage of BT batteries: . Fully maintenance-free .
Specifications Specifications Type Voltage in (V) Capacity in Ah (C20) L (mm) BT 12-1,2 BT 12-2,3 BT 12-2,8 BT 12-2,9 BT 12-3,2 BT 12-5 BT 12-7E BT 12-7 (VdS) BT 12-9 BT 12-9,5 BT 12-12 BT 12-18 BT 12-18i BT 12-20 BT 12-28 BT 12-28S 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 1,2 2,3 2,8 2,9 3,2 5 7 7 9 9,5 12 18 18 20 28 28 97 178 104,5 79,5 134,5 90 151 151 151 151 151 181 181 181 166 166 BT 6-3,2 BT 6-12 6 6 3,2 12 134 151 W (mm) 12V types 43 34,5 47,5 56 67 70 65 65 65 65 98 77 77 77 17
Power Supplies BTL batteries BTL batteries BTL 12-65 BTL 12-100 Our long-standing experience with emergency power systems and uninterruptible power supply units is our guarantee for the highest quality and reliability of EFFEKTA® batteries.
Batteries Specifications Specifications Type Voltage (V) in Capacity in Ah (C20) L (mm) BTL 12-33 BTL 12-45 BTL 12-55 BTL 12-60 BTL 12-65 BTL 12-75 BTL 12-80 BTL 12-90 BTL 12-100 BTL 12-120 BTL 12-120S BTL 12-150 BTL 12-200 12 12 12 12 12 12 12 12 12 12 12 12 12 33 45 55 60 65 75 80 90 100 120 120 150 200 195 198 229 260 350 260 350 306 320 407 330 483 522 BTL 6-100 6 100 194 W (mm) 12V types 130 166 138 169 167 169 167 169 172 177 171 170 240 6V types 170 H (mm) H (mm) max.
Power Supplies Front terminalterminal batteries Front BTL front terminal batteries from EFFEKTA® have the same electrical construction as batteries of the BTL types. However the special dimensions of the batteries mean that they are compact and easy to maintain especially in 19’’ rack cabinets.
Terminals Terminals Batteries More information on request.
Power Supplies BACS BACS BACS, the Battery Analysis & Care System, represents a groundbreaking innovation in the field of battery secured power supplies. This patent-pending technology sets completely new standards in terms of true battery management. BACS guarantees optimum safety and capacity of the battery pack throughout its entire life cycle, thus safeguarding the functionality of your power supplies.
Batteries BACS can find out each damaged or weak battery before the whole system gets critical Integration of BACS technology benefits a complete system (battery pack) in the following ways: - Increase in useful life of the batteries and consequently also the entire battery pack. - Guarantees maximum possible system capacity at all times (increase of up to 20%). - Warnings output in the case of weak or defective systems, in particular display of the defective battery block.
Power Supplies BACS BACS How BACS works and its benefits in comparison to conventional battery-management-systems: Traditionally, batteries in all common UPS systems have been connected and charged in series. The voltage present at the batteries is monitored. This is normally approx. 12-13V or a multiple thereof in accordance with the battery voltage. In this way, it is possible to measure whether the necessary voltage to supply the required battery capacity is available.
Batteries 200 Ah-batteries with BACS in Quasar batterie cabinett 3. Each battery is individually monitored via a dedicated processor-controlled “RTV” module. This also enables defective batteries on a system to be identified.
Power Supplies BACS BACS Structure of the overall BACS system: All batteries in the system are equipped with a control unit (data collection, battery controller) – the “RTV” module. The bus system guides all data to the BACS nerve centre, the core module. This handles the entire management of the battery pack including signal output. Detailed functions of the RTV module: Protection Circuit: Protects the battery module from over-voltage by destroying an irreversible fuse (conducting path).
Batteries Classification of the RTV modules The battery modules (RTVC001 to RTVC004) are designed exclusively for lead batteries with a nominal connection voltage of 12V. The description section CXXX specifies the corresponding capacity class. Class: Capacity range: (battery capacity) This guarantees that the module type (RTVCXXX) is suited to the intended battery capacity.
Power Supplies BACS BACS Descriptions of the core GX module (BACS Webmanager) In summary, the BACS Webmanager provides the following functions: The BACS WEBMANAGER is the core of BACS. The module both provides the link to parent systems (PC, server, web) and also controls all battery modules located in the system. The collected data are managed and saved, and statuses are correspondingly displayed or signalled.
Batteries BACS and communication via the Webmanager Software and functional scope: As a rule the CS121 chip takes precedent over the entire functionality of the core GX module. The CS121 chip essentially handles administration in the same way as the classic USV CS121 SNMP web adapter, the difference being that a BACS system is monitored in this case. The web browser is also used to set the battery parameters to adapt each module to the specifics of the battery manufacturer.
Power Supplies DC UPSUPS DIN rail DIN rail DC 12VDC–48VDC For installation in electrical control cabinets, on DIN rails or anywhere that protected 24V (or 12V and 48V) is required; for instance for entry-control systems, manufacturing and process control systems. The EFFEKTA® battery with 7/12/18Ah is connected to the UPS and supplies fully uninterrupted load up to the end of cell voltage in case of a mains failure. The battery is optionally available in a DIN roptional ail cabinet. 66 .
AC/DC power supplies, chargers, inverters / rectifiers Specifications Specifications Specification Input voltage Output voltage (nominal) Output voltage (physical) L.V.D. threshold Output current nominal Power ( w/o battery) Recommended batt. capacity Dimensions (W x H x D in mm) Weight (w/o battery) Operating temperature Signals Displays Service Safety EMI DT0/012 12A 140W 12V 13.6V 10.5V 21A 240W 210x105x85 1.5kg 1.6kg DC UPS on DIN rail DT0/024 DT0/048 90…264VAC, 47…63Hz 24V 48V 27.2V 54.
Power Supplies DC power supply DC power supply DC ST601 -48 / 60V power supply system including: ‧‧ 1U shelf ‧‧ Max. 2 x 600W rectifier ‧‧ Power distribution ‧‧ Controller Description Main features The DC ST601 power supply system is designed for various applications such as digital access, wireless base stations, microwave links as well as PABX. Numerous options provide solutions for global applications in different environments.
Modular DC power supply systems 48-60V Specifications Specifications Optional accessories Software Programming cable Right hand picture: rear view of rectifier module GR 600 On the far right: front view of rectifier module GR 600 General 48V-version 60V-version Load distribution 48V-version 60V-version 4 pieces / 1 … 30A 4 pieces / 1 … 30A Efficiency ≥92% ≥92% Fuses (DIN 72581-3) EMI, radiated EN 55 022, class B EN 55 022, class B PLD None None Safety EN 60 950, class I EN 60 950, cla
Power Supplies DC power supply DC power supply DC ST602 -48 / 60V power supply system including: ‧‧ 2U 19IN shelf ‧‧ Max. 4 x 600W rectifier ‧‧ Power distribution ‧‧ Controller Description Main features The DC ST602 power supply system is designed for various applications such as digital access, wireless base stations, microwave links as well as PABX. Numerous options provide solutions for global applications in different environments.
Modular DC power supply systems 48-60V Upper left picture: Modular design with up to 4 rectifiers Lower left picture: model with automatic circuit breakers (purpose-built item) Right hand picture: rectifier GR 600 Specifications Specifications General 600W - 48V 600W - 60V Load distribution 600W - 48V 600W - 60V Efficiency ≥92% ≥92% Fuses (DIN 72581-3) 16 pieces / 1… 20A 16 pieces / 1… 20A EMI, radiated EN 55 022, class B EN 55 022, class B PLD None None Safety EN 60 950, class I EN 6
Power Supplies GR 600 600 GR Rectifier 48 / 60V, 600W Left hand image: rear view Right hand image: front view Description Main features GR 600 is a single phase, hot-pluggable, fan-cooled rectifier. The outstanding power density of this product offers the optimum shelf solutions with 1U shelf DC ST601 and 2U shelf DC ST602.
Modular DC power supply systems 48-60V Specifications Specifications Top picture: Output characteristics 600W, 60V Top picture: Output characteristics 600W, 48V General 600W, 48V 600W, 60V User interface Efficiency Losses max. Safety ≥92% 90W EN 60 950, class I UL 60 950 / CAN / CSA – C22.
Power Supplies DC power supply DC power supply DC ST1603 -48 V power supply system consisting of: ‧‧ 3U Shelf ‧‧ Max. 4 x 1600W rectifiers ‧‧ Power distribution ‧‧ Controller Description Features The DC ST1603 is a power supply system for -48V with a maximum power up to 6400W with 3-phase input.
Modular DC power supply systems 48-60V Specifications Specifications Optional accessories Software Programming cable Dummy cover Options Number of rectifiers 1…4 AC connections 3L+PE (220 / 240Vrms L-L)* L + N + PE Display System voltage, current Transient OVP for 3L + N + PE (external) Right hand picture: Rectifier GR 1600 General Load distribution Efficiency ≥ 91 % Fuses (DIN 72581-3) 9 MCBs, 1 ...
Power Supplies GR 16001600 GR Rectifier 48V, 1600W Left hand image: rear view Right hand image: front view Description Main features GR 1600 is a single phase, hot-pluggable, fan-cooled 48V rectifier. The outstanding power density of this product offers the optimum 1U or 3U 19IN shelf solutions.
Modular DC power supplies 48-60V Specifications Specifications Optional accessories Single backplane Triple backplane Blank panel D0106218 D0112006 D0112127 Environment Temperature Power derating Relative humidity -25 … +75°C (-13 … +167°F) +65 … +75°C (+149 … +167°F) 95% max., non condensing Mechanics Width, overall Height, overall Depth, overall Weight 40.8mm (1.6in, 1U) 132mm (5.2in, 3U) 232.5mm (9.15in) 1.25kg (2.75lb) General Efficiency Losses max.
Power Supplies DC power supply DC power supply DC ST2010 -48 / 60V power supply system consisting of: ‧‧ 5U shelf for power distribution and controller ‧‧ 5U shelf for max. 6 x 2000W rectifiers Left hand picture: rear view Right hand picture: front view Description Main features The DC ST2010 is a very compact 19’’ / 5U shelf for the rectifier GR 2000 with a maximum power of 12kW and three phase input.
Modular DC power supply systems 48-60V Specifications Specifications Options Max. number of rectifiers AC connection DC outputs 1…6 3L + N + PE 3L + PE (220 / 240Vrms L-L)* max. 15 *on request Optional accessories Software Programming cable Dummy cover Right hand picture: rear view GR 2000 On the far right: front view GR 2000 General Efficiency Losses, max.
Power Supplies GR 20002000 GR Rectifier 48/60V, 2000W Right hand picture: rear view On the far right: front view Description Main features The GR 2000 is an up to date high frequency switched mode telecom power supply for both 48V and 60V applications. ‧‧ Efficiency ≥ 91% ‧‧ Compact (500W / l) and light (4.4kg) ‧‧ Hot pluggable, all connectors at the rear ‧‧ Fan cooled with air flow monitoring ‧‧ Wide input voltage range: 88 - 276Vrms ‧‧ Power factor ~ 1.
Modular DC power supply systems 48-60V Right hand image: Block diagram Specifications Specifications General Efficiency Losses, max. Safety EMI, radiated Compliant with Cooling Power density ≥ 91% 200W EN 60 950, class I EN 55022, class B EN 300386-2 Fan cooled 500W/l (8.2W / in3) Input Voltage range Volt. range, red. power Inrush current Current maximum Line current Harmonic distort.
Power Supplies Power SystemSystem Controller Controller Power Controller for power supply systems DC ST 601 up to DC ST 2010 / rectifiers GR 600 - GR 2000 PSC 1 PSC 3 Description Description The PSC 1 is a simple power system controller for small power systems. It consists of a compact central unit providing basic I/O periphery, and of an analogue based communication bus to the rectifiers. The user friendly display quickly displays basic information about the current status of the power system.
Modular DC power supply systems 48-60V Top picture: controlling and monitoring of PSC 3 via WEB browser Top picture: «PSC 1 Monitor» - program General PSC1 PSC3 Functions PSC1 PSC3 Safety EN 60 950, class I UL 60 950 CAN / CSA – C22.2 EN 55 022, class B EN 300 386-2 Convection horizontal / vertical IP20 EN 60 950, class I UL 60 950 CAN / CSA – C22.
Power Supplies DC-UPS DC-UPS systems systems Product Description The DC Power Rack DCPR 48-66 is specifically designed for use in telecomunications networks. Fuse-protected 48V power supplies from EFFEKTA® are already in successful operation in TETRA and TETRAPOL networks Available versions: 108V and 216 VDC. Up to 4 rectifier modules PSR308 can be integrated into the subrack. The unit is equipped with a supervisory module combined with a fan tablet and DC distribution. Key Features . High reliability .
Modular DC power supply systems 108-220V System Components Rectifier module PSR327: 110 / 220VDC; 2700W; 12.9A / Key Features: . Single–phase modul with sinusoidal input current (PFC) . Input overvoltage protection . Wide input voltage range (100-254 VAC) . „Hot–Plug–In“ design with backplane connection . High power density . CAN– Bus interface . Integrated decoupling from the DC bus Controll Unit UPC3 with integrated fan Key Features: . Extensive battery management .
Power Supplies Rectifiers Rectifiers Switched rectifiers for parallel-redundant power supply systems of high availability in the energy sector, telecommunications and industry; hot plugin; processorcontrolled, charging voltages and characteristic curves can be adjusted manually and remotely, can be used with all battery types. Example configuration DCR PSR327-10.
Modular DC power supply systems 108-220V Inverters Inverters Right hand picture: Assembly set 19“ sub rack 2U incl. backplane for 3pcs. inverters INV2xx and 1pc. static switch STS207 Left hand picture: single 110 VDC modulet Product description An INV-series inverter includes the newest switching technology with digital control. Due to this fact a dramatic reduction of volume and weight was achieved.
Power Supplies Chargers Chargers Switch-mode chargers for lead-acid batteries, with IUoU-characteristic, timer for float charge, low ripple, leads with battery clips, waterproof (IP67) version available Nominal voltage Output current 135x80x44mm (L x B x H) app. 350g 12V 24V 4A 2A (no pic.) 184x171x54mm(LxBxH) app. 1.7kg Nominal voltage 12V 24V 36V 48V Output current 10A 5.0A 3.3A 2.
DC/DC convertersconverters DC/DC AC/DC For use as a mains source in cars, boats and for other mobile applications. MA8662 MA8862 Switched mode DC/DC converter, output isolated for vehicle use 135x119x46mm (LxWxH) app. 600g Input voltage Output voltage Power contin. Peak power 18-32V 13.2 / 24 / 48V 81W 132W MA8662 Linear regulated CD/DC converter for vehicle use Input voltage 20-32V 129x115x62 Output voltage 13.5V / 6A mm Power contin. 80W (LxWxH) app.
Power Supplies Inverters Inverters EFFEKTA® WR-series WR-012-1000 (front view) Description Features The EFFEKTA® WR-series inverters are ideally suitable ‧‧ Output Voltage 230VAC ‧‧ Input Voltage 12 or 24VDC ‧‧ Compact design ‧‧ Minimal weight ‧‧ Battery low alarm ‧‧ Overload-/voltage reversal-/short circuit-safe in the low and middle performance range as AC power supplies for mobile applications.
AC power supplies, mobile inverters WR-024-3000 (front and rear view) Specifications Specifications Model Power Output voltage Input voltage Dimensions L x B x H Weight WR-012-0150 WR-024-0150 150W 230VAC, 50Hz, mod. Sinus 24VDC 12VDC 155 x 70 x 40mm 0.
Power Supplies Inverters Inverters EFFEKTA® WRS-series WRS-024-1500 Description Features The EFFEKTA® WRS-series inverters are suitable in ‧‧ Output voltage 230VAC ‧‧ Input voltage 12, 24 or 48VDC ‧‧ Battery low alarm ‧‧ Overload-/ voltage reversal-/short circuit-safe ‧‧ Screwable terminals on the rear side the low and middle performance range as AC power supplies for industrial and mobile applications.
AC power supplies, mobile inverters WRS-012-0700 (Identical design of 700/1000W-models except depth) WRS-024-0350 (Identical design of 200/350W-models) Specifications Specifications Model Power Output voltage Input voltage Low.Bat.-Shutdown Dimensions H x B x T Weight WRS-012-0200 Model Power Output voltage Input voltage Low.Bat.-Shutdown Dimensions H x B x T Weight WRS-012-0350 Model Power Output voltage Input voltage Low.Bat.-Shutdown Dimensions H x B x T Weight WRS-012-0700 12VDC 10.
Power Supplies Special DC appliances Special appliances “Powermanager“ Processor-regulated uninterruptible power supply system with 230V/50Hz/200VA AC output, five separate 24V/20A DC-outputs, battery monitoring, protection monitoring, watch-dog, in accordance with VDE0828/ EN60849. Production-redundant Telecom power supply 48V/1800A 48V/2.
Special appliances Product Application Features MD-1 Constructed for industrial systems Online double-conversion with integrated auto bypass Mounting height 4U, to achieve a shortened modular depth of 300mm. All power lines, outputs and sockets for control signal (floating contacts) on hardwired Phoenix terminals. Basic unit Optimised for 19“ switch cabinet MH RM 2000 ® EFFEKTA UPSs are not only suited for use in computers, but also for all sensitive, power-dependent units.
Power Supplies Service Service Overview of maintenance and service contracts 1) Performance-based service . Date: as customer requires . Cleaning the installation . Check-up of the mechanical condition and all installation parts . Voltage check of AC current . . .
Service 3) Full maintenance contract including spare parts and batteries . Date: 1x annually . Cleaning the installation . Check-up of the mechanical condition . . . . . . . . . .
Power Supplies Reference Reference Industry: Banks: Alstom Turbinen...................................................Nuremberg · BHF Bank..........................................................Frankfurt · BASF AG...........................................................Ludwigshafen · Kreissparkasse..................................................Friedrichshafen · BASF AG...........................................................Willstätt · Sparkasse..............................................
Reference Hospitals: Telecommunications: · Albklinik.............................................................Münsingen · Broadnet Mediascape.......................................Hamburg · Bundeswehrkrankenhaus..................................Amberg · DeTe Mobil AG..................................................Bonn · Kliniken Landkreis ............................................Sigmaringen · Deutsche Telekom AG.......................................Weilheim · Krankenhaus St. Martin........
Power Supplies Terms & Conditions Terms & Conditions Terms and conditions for sales and delivery of EFFEKTA - Regeltechnik GmbH, Rottweil Preamble The following terms and conditions for sales and delivery form the basis of the delivery and service contracts of the contractor (user) and supplement the applicable law. They are only applicable to businesses where the contract is made in the course of their business, legal entities of the public law or special authorities under public law. I. Application 1.
Germany International Head Quarter, Sales Department: Sales Department, Service Austria: EFFEKTA Regeltechnik GmbH Rheinwaldstr. 34 D-78628 Rottweil Tel.: +49 741 17451 0 Fax: +49 741 17451 22 E-Mail: info@effekta.com URL: www.effekta.com EFFEKTA Regeltechnik GmbH Industriestraße 4 A-3910 Zwettl, Austria Tel.: +43 2822 200 18 10 Fax: +43 2822 200 18 20 E-Mail: sales@effekta.at URL: www.effekta.at Sales Department North: Production Hungary: EFFEKTA Regeltechnik GmbH Falkenberger Str.