Ultra TT Bluetooth
®
Configuration Procedure
F. Restore Machine-specific Configuration Data
1. Turn on the PDA and start the EFD Ultra TT PDA Application. Tap the Tools button and then
the Database Manager button.
2. From the “Type:” drop-down list, select ACL.
3. From the Databases list select the SNxxxxx.ACL file synced in Step A above.
4. Tap the Download button.
5. The download time should be very quick, resulting in a “Download complete” status
message to the right of the Download button.
6. Exit the EFD application by tapping the “Home” button.
7. Cycle the TT power off and then back on using the red emergency switch and the green
power button.
G. Confirmation
1. When powering up the TT, the Serial Number and firmware version will be displayed on the
LCD panel display for a few seconds. The firmware version should read “V1.2.”
2. To start the EFD Ultra TT PDA application, tap either the Setup or the Program button to
initialize the Ultra TT. The Ultra TT should home the axes and then display the Setup or
Program window.