User`s guide

R
psi
100 x kPa
bar
0
50
100
10
90
40
30
20
60
70
80
0
1
2
3
4
5
6
7
+
+
Features &
Controls:
Front Panel
10
Air Pressure
Pull out the air pressure regulator knob to unlock it (bottom left knob).
Turn the knob clockwise to the desired pressure setting.
To reduce the pressure, turn the knob counter-clockwise until pressure
is lower than needed. Then increase the pressure until you reach the
correct setting.
Push the knob in to lock the pressure setting.
Vacuum
During initial testing and setup we recommend that you keep the vacuum
control shut off (turned completely clockwise; do not force).
Vacuum is required when dispensing thin fluids.
Turn the knob counter-clockwise to the desired vacuum setting.
See page 12 for details on using the Vacuum control.
Air Output Port
Push in the black quick-connect from the EFD adapter assembly to
the air output port, located on the front of the Ultra 870. Twist to lock.
Note: air does not flow through the port until a quick-connect is installed.
air pressure regulator
vacuum regulator
air output
pressure gauge