User`s guide

Specifications
7
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 India+ 91 80 4021 3600 Asia +China: +86 (21) 3866 9006
Sales and service of Nordson EFD dispensing systems are available worldwide.
Cabinet size: 14.3 W x 18.1 H x 17.3 D cm (5.63 x 7.12 x 6.82")
Weight: 2.3 kg (5.0 lb)
Power adapter:
AC input: 100-240 VAC(+/-10%) ~, 50/60Hz, 0.6A
DC output: 24 VDC @ 1.04A
End-of-cycle feedback circuits: 5 to 24 VDC; 100mA maximum
Initiate circuits: Foot pedal, finger switch or 5 to 24 VDC signal
Cycle rate: Exceeds 600 cycles per minute
Time
Range: Programmable from 0.0001 to 999.9999 seconds
Accuracy: Within ±0.05% of the selected time setting
Repeatability: Less than 16 µsec at any time setting
Pressure readout accuracy
Ultimus I (7017041): ±2.0 psi, 0 to 100 psi
Ultimus II (7002003): ±0.3 psi, 0 to 15 psi
Ultimus III: (7017068) ±0.3 psi, 0 to 5 psi
Vacuum readout accuracy
Ultimus I, II or III: ±2.0 in H
2
O, 0 to 18 in H
2
O
Ambient operating conditions:
Temperature: 5°C to 45°C (41°F to 113°F)
Humidity: 85% RH at 30°C non-condensing
Height above sea level: 2000 meters max (6,562 feet)
Meets or exceeds CE and CSA requirements
Ultimus I (7017041)
Air input: 80 to 100 psi (5.5 to 6.9 bar)
Air output: 0 to 100 psi (0 to 6.9 bar)
Ultimus II (7002003)
Air input: 80 to 100 psi (5.5 to 6.9 bar)
Air output: 0 to 15 psi (0 to 1.0 bar)
Ultimus III (7017068)
Air input: 80 to 100 psi (5.5 bar to 6.9 bar)
Air output: 0 to 5 psi (0 to 0.34 bar)
Note: Specifications and technical details are subject to change without prior notification.