User`s guide
Voltage Initiate Circuit
The Ultimus workstation may be initiated with a 5 to 24 VDC signal across pins 1 and 2. The signal
can be momentary (no less than 0.01 seconds) or maintained. A new cycle will begin after the signal
is removed and then applied again.
Mechanical Contact Initiate
The Ultimus can be initiated via the closure of mechanical contacts such as a relay or switch using
pins 7 and 8. Closure of the contacts can be momentary (no less than 0.01 seconds) or maintained.
A new cycle will begin once the contacts are opened and then closed again.
End-of-Cycle Feedback Circuit
A normally closed electronic switch opens at the start of the dispense cycle and closes at the
conclusion of the dispense cycle. The End-of-Cycle feedback on pins 3 and 4 can acknowledge
an active dispense cycle to external equipment.
Input/Output
Connection
22
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 India+ 91 80 4021 3600 Asia +China: +86 (21) 3866 9006
Sales and service of Nordson EFD dispensing systems are available worldwide.