Sales and service of Nordson EFD dispensing systems are available worldwide.
Air Pressure
Air pressure is displayed in psi. See page 20 to change the display of pressure from psi to bar or
kPa. It is shown with the icon of an arrow pushing into a syringe barrel. Follow these steps to set air
pressure.
• Pull the air pressure regulator knob out to unlock it (bottom left knob).
• Turn the knob clockwise to the desired pressure setting.
• To reduce pressure, turn the knob counterclockwise until the display
reads a lower pressure than needed. Then increase the pressure until you
reach the correct setting.
• Push the knob in to lock the pressure setting.
For Ultimus I, II and III units: Set plant air supply within 80 to 100 psi (5.5 to 6.9 bar).
Caution: A pressure regulator of 0 to 100 psi is intended to be provided before connecting unit to
the air supply.
Vacuum
Vacuum is displayed in inH
2
O (inches of water). See page 20 to change the display of vacuum from
inH
2
O to inHg, kPa, mmHg, or Torr. It is shown with the icon of an arrow
pulling out of a syringe barrel. Follow these steps to set vacuum pressure.
• Pull the vacuum regulator knob out to unlock it (bottom right knob).
• Turn the knob clockwise to the desired setting. You can adjust the
vacuum in increments of 0.1 inH
2
O.
• Push the knob in to lock the vacuum setting.
• Caution: Use EFD filter/muffler #7016875 or wear adequate ear
protection when operating the vacuum in close proximity for a prolonged period of time.
Clock
A real time clock is displayed in the top right corner. Follow these steps to set the clock.
• Press MENU.
• Press the down arrow to highlight SET CLOCK.
• Press SELECT.
• Press the left/right arrow to highlight the number to change.
• Press the up/down arrow to adjust the time. Or use the timer dial (top
right knob) to adjust the time or toggle between AM (morning) and PM
(afternoon/evening).
• Press SAVE. This saves the time and automatically returns you to the Home screen.