5.3 TEACHING A DOT
Next, we will program four dots and set the desired dot parameters (Figure A on the
template).
1. In the Program menu, tap “Insert” to start inserting program
instructions. This will open the Select Instruction window.
2. In the Select Instruction menu, select Dot
and tap “OK”.
3. You are now required to teach the first dot position. Tap “Jog” to open the Jog
window. Position the dispense tip to the first point and tap “OK”.
Select a number for Dot Type. Tap “Edit” to
open the Dot Parameter window.
4. If the toggle bracket is selected in the Setup window, the toggle box will be visible
to the Operator to select. Check the “Use Toggle” box if the dispense is to use the
toggle valve/syringe-barrel. Teach the dispense location (Refer to 3 above) using
the toggle valve or syringe-barrel.
Note that when the program is running, the toggle will actuate i.e. move down,
before it begins to move to the taught dispensed location.
5. Enter the desired value for each Dot Parameter field.
Refer to Appendix D for a
detailed description of the different parameters that make up a Dot Type.
When
done, tap “OK”.
6. Tap “Teach Dot” to insert instruction. Each time “Teach Dot” button is pressed the
line number will increment (circled in the left graphics). It allows the user to (1)
verify that the Teach was taken and (2) confirm which instruction is being inserted /
edited.
7. Jog to the next dot location. Select a dot type, if different from the earlier selection.
There can be up to ten unique dot types per program.
8. Tap “Done” once all four Dot instructions have been taught. This will take you back
to the main Program window.
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 Asia +86 (21) 3866 9006