User`s guide
26
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 Asia +86 (21) 3866 9006
Sales and service of Nordson EFD dispensing systems are available worldwide.
EFD
®
TT User's Guide
Version 1.2
3PDA
Before you can start programming, you must first install the Nordson EFD
®
TT PDA software Version 1.2 to your PDA.
Download the Software Installation CD that was included with the PDA to the PC. Once that is done download the EFD PDA
software to the PC. Copy the EFD PDA software to the palmOne Quick Install and then HotSync to install the EFD PDA
software to the palm.
Currently, only selected PDA handhelds
6
can be used with the Nordson EFD
®
TT
programming software. However, it is intended that the software will be available
for other makes of PDA's. Please check with your EFD
®
TT salesperson for more
information.
Please refer to the EFD
®
TT User CD for detailed installation instructions.
The EFD
®
TT software is divided into three specific sections.
Setup:
Setup basic system parameters such as valve selection, system-park,
purge cycle and initial offsets.
Programming:
Teach origins, specific points and dispensing parameters.
Tools:
For troubleshooting and advanced software upgrades.
CAUTION:
Changes in this area should be performed under strict supervision or
by your NordsonEFD
®
TT representative. Failure to do so may cause programs not
to operate or run properly.
Next, plug the pre-configured Socket Adapter that came with your machine to the rear of the RS232 COM port of the EFD
®
TT System. Power up the EFD
®
TT and verify that the Socket adapter is blinking.
Then, turn the system on by pressing the green power button on the front panel. In the Main Menu, select
Tools
>
Bluetooth
>
Discover
. Wait about 15 seconds to list any wireless devices in range. Highlight the EFDSNxxxxx
(the”xxxxx” is the 5-digit serial number of the EFD
®
TT unit) entry in the list, then tap “Connect”.
Enter 1234 as the passkey for the Socket Adapter. Verify that the “Add to trusted devices list” option is NOT selected, then
tap “OK”. Your PDA is now paired with the EFD
®
TT unit.
6
The minimum Palm OS version is 4.0. The following Palm handhelds have been tested and are known to work with the Nordson EFD
®
TT software and hardware:
With the Teach Pendant Cable (700818): Zire
™
71, Tungsten
™
C, m515, m505 and the m500. The Tungsten T, T2 and T3 can be used but only with
Firmware version 1.1 and above. Sony Clié
®
PEG-TJ37 may also be used but requires baud rate on machine to be switched (See your Nordson EFD
®
TT
Representative for further instructions).
With Bluetooth: Zire 72, Tungsten T, T3, T5 and E2.