2.6 MOUNTING LASER POINTER
Some customers may prefer to use a laser pointer to aid in positioning the X or Y dispense programming points. Note that
the laser pointer should be used in conjunction with the height sensor. The height sensor, along with the dot/line parameter
setting of the “dispense gap” will determine the z-height at the dispense point. EFD provides a laser pointer and bracket
(#700820) that can be easily mounted onto the EFD
®
TT.
To connect the optional laser pointer teaching device to the EFD
®
TT:
1. Secure the laser to the Z-head by sandwiching the laser bracket behind
the syringe or valve bracket. Connect the laser pointer’s red wire to
terminal pin #6 (+5VDC power supply) on the Z-head connecter and
the blue wire to terminal #9.
2. Next, check the functionality of the laser.
a. Using the PDA, select “Program” from the “Main” screen.
b. Tap the top left-hand corner of the Program screen and select
“Util” from the menu bar.
c. Select “Toggle Laser”. This will turn the laser pointer drive on.
To turn the laser pointer off, select “Toggle Laser” again.
Note:
the laser should be turned off when not in use to extend
the life of the laser and to prevent accidental exposure.