2.5.1 SYRINGE BARREL
This section also applies to EFD dispensing valves 5800MP, HP4X, and HP7X, in addition to EFD’s range of syringe barrels.
First, install the appropriate bracket e.g. universal syringe barrel bracket (P/N 700814) for
syringe barrel installations, onto the Z-carriage. Insert the holding pins into the holes on the back
plate to fit the size syringe barrel you are using. Insert the luer end of the syringe barrel into the
syringe barrel stop and twist the syringe barrel onto the disposable luer extender.
Attach the syringe barrel adapter to syringe barrel and plug the male quick-connect into the
female quick-connect located on top of the Z-head labeled P1 (for high-viscosity fluid, 0-100 psi)
or P2 (for low-viscosity fluid, 0-30 psi). Attach your dispensing tip to the bottom of the luer
extender.
To adjust the vacuum for low-viscosity fluids, use the vacuum control
knob located on the front panel. The vacuum control knob is
connected in parallel to both P1 and P2 pneumatic circuits.
Adjust the height sensor probe so that it is clear from obstruction
during your programmed routine. Be sure that you teach a new
Z-Offset after adjustment of height sensor probe. Refer to the Quick
Start Installation Guide on how to correctly adjust the height sensor
probe.
21
Tip: Use blue pistons when dispensing low-viscosity
fluids from syringe barrels. Regulate main air
pressure to 50 psi.