User`s guide
2Setup
2.1 Preparing the Work Area
Place the EFD
®
TT system on a stable table or bench. The EFD
®
TT needs enough space behind the machine (at least
250mm) to allow for the tooling to move to its home position. This space also ensures the fan duct on the back of the
machine is not obstructed and thereby allows for air-cooling of the internal electronics.
Allow enough room to place fluid reservoir pressure tank beside the machine. Fluid cartridges may be mounted to the
uprights using the M8 T-Slots on either side of the EFD
®
TT.
2.2 Main Air and Electrical
It is important that you have dry, clean filtered air that is aerosol free
to prevent problems with the pneumatic system of
your new EFD
®
TT system. Input air should not be more than 100 psi. If you have any doubts about your air supply, you
should purchase one of the two filter regulator sets listed below.
Main air input is located immediately to the left of the Fan Duct on the back panel of the machine and accepts 6mm
diameter tubing. Simply push the 6mm tubing into the push-fit connector.
Each unit is shipped with two power cords. Plug the appropriate power cord into the three-prong power cord slot located on
the back of the machine next to the main power circuit breaker. The machine is equipped with a self-regulating power supply
and will accept 100VAC ~ 240VAC +/- 10%, 50 ~ 60 Hz input voltage.
17
2000F755TT Five-micron filter regulator
Order this if you do not have dry clean filtered
factory air supply
2000F756TT Five-micron filter regulator
with coalescing filter to remove aerosols from
air supply
Plant air, 125 psi maximum to regulator.
Output from regulator should be a minimum
of 80 psi, maximum of 100 psi.
Air input
hose