User`s guide
Initial Test
Procedures
Testing in Timed Mode
• Follow steps in “Testing in Steady Mode” to purge your dispense tip with fluid.
• Change to Timed mode by pressing the Teach button twice to reset the display to 000 seconds.
• Set time to 0.25 seconds.
• Rest the dispense tip on the Dot Standards sheet.
• Press the foot pedal to activate the dispense cycle. Note: the pedal only needs to be pressed for a
moment. The complete time will run once you activate the dispense cycle.
• Changing the time changes the deposit size. If your dot is too small, increase the dispense time
to increase the deposit size. If your dot is too large, decrease the dispense time to decrease your
deposit size.
Testing in Teach Mode
• Follow steps in “Testing in Steady Mode” to purge your dispense tip with fluid.
• Change to Teach mode by pressing the Teach button once so that the digital display flashes.
• Rest the dispense tip on the Dot Standards sheet.
• Press the foot pedal to establish your dot size. Tapping the foot pedal repeatedly will have a
cumulative effect on the dot size and dispense time.
• Continue to press the foot pedal until you achieve the correct deposit size.
• Save the dispense time setting you just created by pressing the Teach button again. This
automatically exits Teach mode and returns you to Timed mode.
• If needed, press the Teach button twice to reset to 0 and start over.