User`s guide

steady mode
Features &
Controls:
Front Panel
10
Digital Display
Teach button . In Teach mode, you can “teach” the deposit based
on physical size.
Press the button once, so that the digital display flashes.
Press and hold the foot pedal to establish your deposit size.
Tapping the foot pedal repeatedly will have a cumulative effect
on the dot size and dispense time.
Press button again. The flashing stops. Your dispense
time is now automatically stored, with the decimal displayed
in the appropriate position.
Press twice to clear the display. Any decimals will disappear and
the time range will reset to 000.
Steady button . In Steady mode, the foot pedal controls fluid flow.
Press once and the display changes to dashes (---).
Press again and dashes are replaced with dispense time setting.
Steady mode is used for filling the dispense tip, dispensing
beads and stripes of material, and making by-eye deposits.
Decimal button . Press the Decimal button to move the
decimal. When no decimal shows, the dispense time range is .000
to
.999 seconds. Note: You cannot adjust the decimal from Teach mode
(when display is blinking).
Time Set buttons . Each button sequentially controls the display digit
in that panel. Each press advances the display from 0 to 9 and repeats.
air pressure regulator
vacuum regulator
air output
teach
pressure gauge
time set buttons
decimal button
digital display
050
50
0
.
0
0 5
.
.050 seconds
0.50 seconds
5 seconds