User Guide

Specifications
6
Cabinet size: 18.9 W x 7.1 H X 15.9 D cm (7.5 x 2.8 x 6.3")
Weight: 1.0 kg (2.2 lbs)
Input voltage: Selectable 100/120/220 VAC
Input frequency: 50/60 Hz
Input power: 14/12 VA
Internal voltage: 24 VDC
Standard air input: *40 to 110 psi (2.8 to 7.5 bar)
*WARNING: DO NOT exceed 110 psi (7.5 bar) or damage to the unit may occur.
Air usage: Up to 55 L/min (3 CFM). See page 11 for details.
Temperature control: +/- 0.1ºC from 10ºC to 40ºC (50°F to 104°F)
Ambient operating condition limits:
Temperature: -10ºC to 55ºC (14ºF to 131ºF)
Humidity: 85% RH at 30ºC non-condensing
Height above sea level: 2000 meters max (6,562 feet)
Under normal operating temperatures, the ProcessMate 6500 can maintain dispense process chamber
set point within +/- 0.1ºC, from 10ºC to 40ºC (50°F to 104°F). Normal operating conditions are
considered to be an ambient air feed between 15ºC and 27ºC (60ºF and 80ºF). The ProcessMate 6500
will operate quite effectively outside of these temperatures, but it will affect the maximum and minimum
temperatures the unit can generate.
Note: Specifications and technical details are subject to change without prior notification.