US: 800-556-3484 UK: 0800 585733 Mexico: 001-800-556-3484 technical@efd-inc.
Setup and Operation air cylinder Step 1. Remove reservoir retainer reservoir retainer plunger IMPORTANT: Confirm that a white piston is between the fluid and the plunger. ULTRA™ reservoir system dispensing tip Step 2. flange alignment Install dispensing tip on reservoir. Insert filled reservoir into retainer and align flange with slot as shown.
Step 3. quick-connect + Changing Reservoirs When a reservoir is empty, the window in the air cylinder will turn red. Remove reservoir retainer. Then, remove empty reservoir and discard. Changing Tips Remove tip retaining cap and invert. Align slot with wings on dispensing tip. Turn tip retaining cap counterclockwise to remove tip. Attach a new tip and tighten tip retaining cap securely. For parts list, see back cover. window + Install retainer and rotate clockwise to secure.
air cylinder cap #5903 reservoir retainer #5925 tip retaining cap #5904 retaining ring #5924 drive plunger #5908 dowel pin #8176-11 jam ring #5922 shaft bushing #5927 spring air cylinder #5926 #5923 piston U-cup #5909 piston and shaft includes U-cup (Buna-N) #5928 O-ring (Buna-N) #72530A HP7x Troubleshooting If the HP7x should cease to operate, service of the piston U-cup and shaft bushing may be required. Please follow procedure below: 1. 2. 3. Remove air cylinder cap. 4.