User`s guide

Connect Power
1. Connect the power cord to the back of the dispenser.
2. Plug the power cord into your local power source.
3. Turn the power switch on the front panel to the on position.
Connect Foot Pedal
The Ultimus V can be operated using the foot pedal provided, or by an external device via a
DB-15 connector.
1. Plug the foot pedal into the connector on the back of the dispenser.
2. You can also operate the Ultimus V with an optional finger switch or a 5 to 24 VDC pulse.
Connect Air Input
Note: Clean, dry, filtered factory air is required to meet warranty. To ensure air quality,
install the five-micron filter regulator provided with the Ultimus V.
1. Push one end of the air input hose into the Air In fitting on the back of the dispenser.
2. Connect the other end of the air input hose to the filter regulator supplied with the
Ultimus V dispenser.
Note: Input air should be set at least 15 psi (1.0 bar) - or more - higher than dispensing
pressure, up to a maximum of 100 psi (6.9 bar).
Connect Air Output
Push the connector on the adapter/Optimeterâ„¢ into the connector on the front of the
Ultimus V and twist clockwise to lock.
Attach Syringe Barrel and Tip
1. Secure an EFD syringe barrel filled with your fluid to the adapter/Optimeterâ„¢.
2. Replace the tip cap with an appropriate EFD precision dispense tip.
Initial Setup
For Testing