Specifications

5
Hookup
Connect the air input hose to a plant air source. Set plant air
supply within 80 to 100 psi (5.5 to 6.9 bar). Where required, use
an EFD five-micron filter regulator #2000F755 (see Warranty).
Attach the air input hose coupling to the dispenser. Pull back
metal ring to attach to dispenser.
Plug in the polarized foot pedal connector.
Check the voltage label on the input voltage selector cartridge.
To change the voltage, remove the voltage selector from the
cartridge, rotate it and position the correct voltage to show
through the cartridge window. Replace the cartridge into the
power cord receptacle and insure that both sides snap securely
into position. Install the power cord.
Note: For 900-15 and 900-CA dispensers, use the test barrel filled
with clear fluid and the red 25 gage tip. Refer to “Making Timed
Deposits of Watery-thin Fluids” on page 10.
Attach the 10cc barrel pre-filled with blue, nontoxic test fluid
(included with the dispenser) to the 10cc adapter head.
Take the 10cc barrel adapter assembly (#5150 on the adapter
head) and insert the black, male quick-connect into the air
output fitting on the front panel and turn clockwise to lock. Place
the barrel in the barrel stand.
During the initial testing, you will not use the vacuum control.
Keep this control shut off (turned completely clockwise—do not
force).
Spare Fuse
Voltage Value
220
120
100
Cartridge Window
(check voltage indicated)
Note: The dispenser is
shipped with the fuse cartridge
set for 120 VAC input.