Connect Foot Pedal
The Performus is normally operated using
the foot pedal provided.
• Connect the foot pedal to the back of
thePerformus.
• If you prefer, you can also operate the
Performus with an optional finger switch
(EFD part 7016718).
Attach Syringe Barrel/Dispense Tip
• Attach an EFD syringe barrel filled with your
fluid to the adapter assembly.
• Snap the safety clip on the adapter hose
closed to prevent dripping. Remember to
unsnap the clip when ready to dispense.
• Replace the tip cap with an EFD precision
dispense tip.
• Place the syringe barrel in the barrel holder.
Connect Air Output
• Push in the black male quick-connect on
the syringe barrel adapter into the front of
the Performus.
Twist clockwise to lock.
Initial setup is now complete. At this point you are ready to set up your