User`s guide
11
Connect Air Supply
Note: Clean, dry filtered factory air is
required to meet warranty. If your air supply
is not filtered, order the EFD five micron filter
regulator (EFD part 7016547).
Turn the air regulator adjustment knob to
zero before connecting the main air input
to the Performus.
• Push one end of the 6mm air input hose into
the input fitting on the back of the
Performus.
• Connect the other end of the hose to your
plant air supply.
• Set plant air supply at minimum 5.5 to 6.9
bar (80 to 100 psi).
• Keep the vacuum feature turned off by
turning the vacuum control knob all the
way counter-clockwise. If the fluid you are
dispensing is a thin, watery, or low viscosity
consistency, proceed to “Using the Vacuum
Control Feature for Low Viscosity Fluids.”
Connect Power
• Locate the DC input connection on the back
of your Performus dispensing system.
• Insert the DC Plug securely into the input
connection.
• Select the proper adapter from the power
supply plug kit and then connect the power
supply to a grounded power source.
Note: The power supply is multi-voltage,
therefore no external adjustments are required.