Specifications

www.nordsonefd.com info@nordsonefd.com Sales and service of Nordson EFD dispensing systems are available worldwide.
Preventive Maintenance 21
Preventive Maintenance
WARNING: Before performing any maintenance, set
the System Pressure Switch to the Off position and
depressurize the tank reservoir by lifting the lever
on the tank pressure relief valve.
NOTE: Dispose of used oil filters in accordance with
local environmental regulations.
The MicroCoat System is designed for long life with minimal maintenance. To ensure
trouble-free performance, follow these precautions and preventive maintenance steps:
1. Always use clean lubricant.
2. Check for residue at the bottom of the tank reservoir and clean if necessary.
3. Do not clean the MC685M or the MC686M tank with chlorinated solvents, aromatic
hydrocarbons or any fluid that will attack acrylics. Use only soap and water, or
mineral spirits to clean acrylic tank surfaces.
4. Operate the system with clean, dry, oil-free air. Drain the bowl on the five micron
filter regulator whenever moisture or oil is present.
5. Replace lubricant filter (#7017347) every 6 months or 1000 hours of operation.