Specifications
www.nordsonefd.com info@nordsonefd.com Sales and service of Nordson EFD dispensing systems are available worldwide.
6. Open the valve on the filter adapter
until all the air is removed.
7. Check for leaks around the filter and
all connections between the tank and
controller.
8. Select one valve and open the appro-
priate
Flow Control
knob about
five full turns (counterclockwise) to fill
the hose and prime the valve.
9. When the lubricant flows in a steady
stream, the valve is primed. Close the
Flow Control
(turn clockwise).
10. Repeat steps 8 and 9 for each valve.
Check All Connections
1. Check that all connections are correct and
secure.
2. Verify that the
System Pressure
switch is
set to the
Off
position and the mode switch is
set to the
Auto/Run
position.
3. Check that the input air supply is connected
and set at 4.14 bar (60 psi).
Fill the Tank Reservoir
1. Unscrew the tank cap and fill the tank reservoir
with lubricant to the level indicated on the tank
label.
Caution:
Do not overfill. Overfilling
may cause lubricant to flow back
into the regulator in the controller.
2. Reinstall the tank cap.
Prime the System
1. Set the
System Pressure
switch to
On
.
2.
Adjust the Tank Air Pressure regulator to
1.03 bar (
15 psi
). Do not set pressure lower
than 0.83 bar (12 psi).
3. Turn the
Nozzle Air
pressure regulator knob
counterclockwise as far as it will go to prevent
nozzle air from flowing while priming the valves.
Note:
Regulator knobs have a push to-lock,
pull-to-unlock feature.
4. Turn all
Flow Control
knobs completely
clockwise until closed.
5. Set the mode switch to
Manual/Setup
.
System Setup 19
Continued on page 20
System Setup